NOTE:<br />

• The names and values in the NT registry are case sensitive.<br />

13.2.4 How to Configure the SNMP Trap<br />

1. In order to let the SNMP trap working properly, the<br />

"<strong>RAID</strong>COMM.INI" file must be copied in the system root directory<br />

(\WINNT).<br />

2. The Descriptions of Contents of the "<strong>RAID</strong>COMM.INI"<br />

Examples:<br />

[TRAP]<br />

PERIOD=30<br />

SEVERITY=0<br />

Comments:<br />

A There should be a section of "trap". The values of “PERIOD”<br />

specify the minimum interval of sequential traps. It is in seconds.<br />

For example, as above, it is 30 seconds.<br />

B The value of "Severity " is a filter to mask the traps that is less than<br />

its value. The value of "Severity" is considered when the value of<br />

"PERIOD" is positive.<br />

C The SNMP agent communicates to the <strong>RAID</strong> controller through inband<br />

SCSI by default. To change the communication route to RS-<br />

232C, please refer to the next paragraph.<br />

D While the Text <strong>RAID</strong> Manager is running and communicates to<br />

the <strong>RAID</strong> controller through the in-band SCSI, the SNMP traps<br />

will not be able to send. It is a must to exit the Text <strong>RAID</strong> Manager<br />

in order to send the SNMP trap properly.<br />

E While the Text <strong>RAID</strong> Manager is running locally, the remote<br />

SNMP connection (GUI via SNMP) cannot be established. It is a<br />

must to exit the local Text <strong>RAID</strong> Manager in order to perform<br />

remote administration via SNMP.<br />

3. The SNMP agent communicates to the <strong>RAID</strong> controller through inband<br />

SCSI by default. To change the communication route to RS-<br />

232C, please add:<br />

[<strong>RAID</strong>0]<br />

CONNECT=COM1<br />

BAUDRATE=9600<br />

Comments:<br />

A Without this section, the SNMP agent will try to communicate<br />

with the <strong>RAID</strong> controller by the default route - in-band SCSI.<br />

B The "[<strong>RAID</strong>0]" refers to the first <strong>RAID</strong> controller connected. If<br />

more than one controller are connected, the second <strong>RAID</strong><br />

controller should have another section titled "[<strong>RAID</strong>1]".<br />

In-band Text <strong>RAID</strong> Manager and SNMP Agent Installation 13-5