Environment Management:<br />

B-8<br />

SAF-TE/S.E.S. support Supported. The SAF-TE/S.E.S. modules can be<br />

connected to the drive channel, the controller will<br />

detect errors from SAF-TE/S.E.S. devices or notify<br />

drive failure via SAF-TE/S.E.S..<br />

• Both SAF-TE/S.E.S. via drive and device-selfinterfaced<br />

are supported.<br />

• Redundant SAF-TE/S.E.S. devices are<br />

supported<br />

• Multiple S.E.S. devices are supported<br />

SAF-TE/S.E.S. polling User configurable (50ms, 100ms, 200ms, 500ms,<br />

period<br />

ISEMS (<strong>Infortrend</strong> Simple<br />

Enclosure Management<br />

Service)<br />

1~60sec)<br />

Supported.<br />

Multiple SAF-TE/S.E.S. Supported.<br />

modules on the same<br />

channel<br />

Multiple SAF-TE /S.E.S. Supported.<br />

modules on different<br />

channels<br />

Mapping SAF-TE/S.E.S. Supported.<br />

device to host channel for<br />

use with Host-based SAF-<br />

TE/S.E.S. Monitor<br />

Dual-LED drive status Supported. Both single-LED and dual-LED drive<br />

indicators<br />

status indicators are supported.<br />

SAF-TE/ S.E.S. Temperature Supported. Display the temperature value provided<br />

value display<br />

by enclosure SAF-TE module (if available).<br />

Fault-bus support Provides the simplest implementation for the<br />

enclosure management. All fault-bus input/output<br />

signals are active-high/active-low user adjustable.<br />

On-board controller voltage Supported. Monitors the 3.3V, 5V, and 12V voltage<br />

monitors<br />

status. Event trigger threshold user configurable.<br />

On-board controller Supported. Monitors the CPU and board<br />

temperature sensors temperature status. Event trigger threshold user<br />

configurable.<br />

Enclosure redundant power Supported. Fault-Bus/SAF-TE/S.E.S./ISEMS<br />

supply status monitoring<br />

Enclosure Fan status Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS<br />

monitoring<br />

Enclosure UPS status Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS<br />

monitoring<br />

Enclosure temperature Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS<br />