[8.A2] OP20 RS232 interface protocol: COM 1<br />

Various ECG <strong>and</strong> Ergospirometry<br />

systems support the h/p/cosmos coscom<br />

protocol. Individual adaptation of<br />

protocol on request. For further<br />

information about the h/p/cosmos<br />

coscom protocol see www.coscom.org<br />

We recommend to use the h/p/cosmos<br />

coscom protocol, as it provides a high<br />

safety <strong>and</strong> functionality st<strong>and</strong>ard.<br />

h/p/cosmos para control ® <strong>and</strong><br />

h/p/cosmos para graphics ® exclusively<br />

work with the h/p/cosmos coscom<br />

protocol.<br />

For advanced h/p/cosmos coscom v3<br />

connections with Baudrate 115200<br />

please select OP20=20 . Please note<br />

that the connected peripherie/software<br />

must be approved for h/p/cosmos<br />

coscom v3 with Baudrate 115200 (for<br />

example h/p/cosmos para control 4.0).<br />

OP21 RS232 interface protocol: COM 2<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 102 of 213<br />

optional settings<br />

§ indicates flashing: number of the RS232 interface protocol<br />

$ <strong>and</strong> % reports:<br />

OFF = RS232 not active / no protocol / interface deactivated<br />

1 = h/p/cosmos coscom v1, v2, v3 with Baudrate 9600 bps<br />

( st<strong>and</strong>ard setting COM 1 <strong>and</strong> COM 2)<br />

2 = JAEGER OXYCON (up to 1995); if available use: h/p/cosmos<br />

coscom (= 1)<br />

3 = Printer protocol (serial printer or converter required)<br />

4 = Free<br />

5 = Pacer treadmill emulation (max. 12.7 km/h)<br />

6 = MAX 1 (GE Marquette) EKG; if available use: h/p/cosmos<br />

coscom (= 1)<br />

7 = Trackmaster treadmill emulation in km/h<br />

8 = Trackmaster treadmill emulation in miles per hour<br />

9 = custo card ECG (MS DOS-Version); if available use: h/p/cosmos<br />

coscom (= 1)<br />

10 = Loop Back Test (special test plug required, available at<br />

h/p/cosmos)<br />

11 = SunTech Tango blood pressure monitor<br />

12 = Remote Control Hardware Terminal MCU 4<br />

(special hardware required)<br />

13 = Burdick T 500 treadmill emulation<br />

14 = Burdick T 600 treadmill emulation<br />

17 = Chipcard reader Ergofit (special hardware required) – only<br />

available at MCU4 (all firmware versions)<br />

or MCU5 firmware < v1.03.x<br />

18 = Chipcard reader Proxomed (special hardware required) – only<br />

available at MCU4 (all firmware versions) or MCU5 firmware <<br />

v1.03.x<br />

20 = h/p/cosmos coscom v3 with Baudrate 115200 bps<br />

See descriptions above<br />

OP23 RS232 interface protocol COM 4 § indicates flashing: number of the RS232 interface protocol<br />

$ <strong>and</strong> % reports:<br />

OFF = RS232 not active / no protocol / interface deactivated<br />

18 = Chip-card reader PROXOMED (special hardware required)<br />

20 = h/p/cosmos coscom v3 / Baudrate 115200 bps<br />

22 = Polar W:I:N:D: - System (weitere Einstellungen in Benutzer<br />

Option OP19 und Administrator Option OP16)