[10.I1] E52 Error of<br />

Card Err<br />

01<br />

Card Err<br />

02<br />

Card Err<br />

03<br />

Card Err<br />

04<br />

RS485-cable motor control<br />

cable-defect or bad contact at the<br />

connection MCU/frequency-inverter.<br />

Only applicable at digital control (RS485)<br />

of MCU5/frequency inverter<br />

Error chip-card-drive<br />

(not all models)<br />

Error chip-card-drive<br />

(not all models)<br />

Error chip-card-drive<br />

(not all models)<br />

Error chip-card-drive<br />

(not all models)<br />

= „E 52“ ! „FU“ flashing<br />

§ $ % „HELP“ flashing<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 152 of 213<br />

trouble shooting<br />

The MCU5-control-boards always sends a reset-message at every<br />

switch-on of the device. After 10 time-out-failures in a row, the MCU<br />

generates the E52 error-message. This is equivalent to a missing<br />

connection (e.g. cable-defect) in the cable from MCU5 to frequencyinverter.<br />

N Check RS485 plug at the MCU5 control board<br />

N Check RS485 plug at the frequency inverter<br />

N Check RS485 plug at the optocoupler board<br />

N Contact authorized service engineer<br />

= „CARD“ ! „ERR“ " „1“<br />

Running <strong>machine</strong> is still functioning (except chip card function)<br />

N Communication malfunction with Chip-Card<br />

N Insert chip-card to the chip-card-drive<br />

N Replace chip-card<br />

N Replace chip-card-drive<br />

N Contact authorized service engineer<br />

= „CARD“ ! „ERR“ " „2“<br />

Running <strong>machine</strong> is still functioning (except chip card function)<br />

N Too many training weeks<br />

N Check period of training<br />

N Check system date <strong>and</strong> time settings of the <strong>running</strong> <strong>machine</strong><br />

N Re-program chip-card<br />

= „CARD“ ! „ERR“ " „3“<br />

Running <strong>machine</strong> is still functioning (except chip card function)<br />

N Test ident on the chip-card not accepted<br />

N False chip-card in the chip-card-drive<br />

N Insert the correct chip-card<br />

= „CARD“ ! „ERR“ " „4“<br />

Running <strong>machine</strong> is still functioning (except chip card function)<br />

N unknown chip-card-malfunction<br />

N no card identified<br />

N check chip-card<br />

N insert correct chip-card<br />

N reprogram chip-card