[6.E] Emergency-Stop / Emergency-Off<br />

When in danger of falling or in any<br />

emergency case please press the<br />

red button of the emergency-stop<br />

at the UserTerminal. At devices<br />

without UserTerminal the red<br />

emergency-stop-button is located<br />

directly at the h<strong>and</strong>rail.<br />

In order to switch on the device<br />

again, unlock the Emergency-stop<br />

by pulling or by turning it slightly<br />

to the left (depending on the<br />

type).<br />

installation & commissioning<br />

picture left unlatching by turning<br />

picture below unlatching by pulling<br />

Running <strong>machine</strong>s for sports <strong>and</strong> fitness with manufacturing date before 12/2007 will be ready for operation immediately<br />

(pay attention to the display). Running <strong>machine</strong>s with manufacturing date after 12/2007 resp. all treadmills for medical<br />

application (independet of manufacturing date) have to be switched on with the white main power on „I“ key (until 2003<br />

green “ON” or “I” key) again. Before switching it on again, however, wait for at least 1 to 2 minutes (3 phase devices: 2<br />

to 3 minutes). As mentioned above „Switching the device off“.<br />

N Use the emergency-stop only if in danger.<br />

N The emergency-stop is not to be used as a normal stop-key.<br />

picture type of stop function interface<br />

communication<br />

Safety Stop =<br />

Emergency Stop<br />

on UserTerminal<br />

(st<strong>and</strong>ard on all<br />

<strong>machine</strong>s with<br />

UserTerminal)<br />

Safety Stop =<br />

Emergency Stop<br />

External <strong>and</strong>/or<br />

additional<br />

emergency stop<br />

mushroom head<br />

type.<br />

N palm switch is hit<br />

N <strong>running</strong> belt & inclination<br />

system stop fast<br />

N <strong>machine</strong> is cut off from main<br />

power of drive motor <strong>and</strong><br />

inclination system<br />

N display, keyboard <strong>and</strong><br />

interface inactive<br />

N mushroom switch is hit<br />

N <strong>running</strong> belt & inclination<br />

system stop fast<br />

N <strong>machine</strong> is cut off from main<br />

power of drive motor <strong>and</strong><br />

inclination system<br />

N display, keyboard <strong>and</strong><br />

interface inactive<br />

communication<br />

interrupted<br />

during cut off<br />

from main<br />

power<br />

communication<br />

interrupted<br />

during cut off<br />

from main<br />

power<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 58 of 213<br />

how to restart<br />

N wait 1 minute<br />

N pull palm switch<br />

N push “power on”<br />

button / main<br />

power<br />

N press START key,<br />

N or new comm<strong>and</strong><br />

through interface<br />

N wait 1 minute<br />

N pull mushroom<br />

switch<br />

N push “power on”<br />

button / main<br />

power<br />

N press START key,<br />

N or new comm<strong>and</strong><br />

through interface