[9.E] Control <strong>and</strong> tightening of the <strong>running</strong> belt<br />

maintenance & safety inspections<br />

The belt can loosen after some time of use or when it has been adjusted in a wrong way, so that a backlash occurs with<br />

every step between the driving shaft <strong>and</strong> the belt (slowing down of the belt at weight application through the step).<br />

In this case check the belt tension as follows:<br />

N Visual inspection of the surface for cracks. In case of a crack<br />

replace <strong>running</strong> belt immediately.<br />

N Open the motor hood in the front. Take care that nobody gets<br />

their h<strong>and</strong>s into the motor.<br />

N Now press the "START/Enter" key to get into manual mode<br />

<strong>and</strong> select with the help of the "+"/"-" keys a speed of 1 up to<br />

1.5 km/h.<br />

N St<strong>and</strong> on the <strong>running</strong> belt (if necessary with 2 people). Hold<br />

on to the side h<strong>and</strong>rails with both h<strong>and</strong>s <strong>and</strong> try to block the<br />

<strong>running</strong> belt by stemming yourself against the <strong>running</strong> belt<br />

rotation with your feet.<br />

N Try to block the <strong>running</strong> belt for max. 10 seconds. The driving<br />

shaft <strong>and</strong> the motor shaft should not be turning during that<br />

time. Otherwise the <strong>running</strong> belt has to be tightened (or the<br />

driving belt).<br />

If the <strong>running</strong> belt is being blocked for too long, then the motor regulation can switch off because<br />

of over current, which will be indicated by an error display. In this case, switch off the device for 5<br />

minutes <strong>and</strong> then switch it on again. The belt tension should not have more than 0.5 %, for<br />

otherwise it could lead to damages on the belt, on the shafting or the bearings!<br />

For models with a <strong>running</strong> surface up to 190 x 65 cm the belt is tightened with a hex socket (8 or 10 mm) at the rear<br />

drive shaft [2]. All bigger models are tightened at the front drive shaft [5]. Mark of 1000 mm [1] applied when belt [4]<br />

absolutely loose. Tighten belt, until mark exp<strong>and</strong>ed up to between 1004 <strong>and</strong> 1005 mm (= 0.4 to 0.5 %).<br />