[10.I1] E20 Elevation system<br />

exceeded the max. value<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 148 of 213<br />

trouble shooting<br />

= „E 20“ ! „ELEV“ flashing<br />

§ $ % „HELP“ flashing<br />

Running <strong>machine</strong> is still functioning (except for the lift device)<br />

N Lifting element exceeded the maximum value. The combined<br />

0% / maximum % -contact had been activated<br />

N Incorrect measurement of angle of elevation<br />

N Maybe wrong adjusted, dirty or defective elevation sensor<br />

N Contact authorized service engineer<br />

E21 Error of elevation system = „E 21“! „ELEV“ flashing<br />

§ $ % „HELP“ flashing<br />

Running <strong>machine</strong> is still functioning (except for the lift device)<br />

N Maybe technical blocking of elevation (e.g. overload)<br />

E30 Error of<br />

speed / distance measurement<br />

N Maybe power supply too weak because of an extension cable<br />

etc.<br />

N Check power supply <strong>and</strong> power cord<br />

N Maybe elevation sensor adjustment is wrong or the sensor is<br />

dirty or defective<br />

N Contact authorized service engineer<br />

= „E 30“ ! „INCR“ flashing<br />

§ $ % „HELP“ flashing<br />

Running <strong>machine</strong> can still operate for a few seconds at speed of<br />

max. approx. 1 km/h<br />

N Maybe technical blocking of <strong>running</strong> belt (e.g. alien element,<br />

towel trapped in device)<br />

N Maybe power supply too weak because of an extension cable,<br />

etc.<br />

N Check power supply <strong>and</strong> power cord<br />

N Maybe speed sensor adjustment is wrong, the sensor may be<br />

dirty or defective or the speed calibration is wrong. OPTION 34<br />

N Safety delay time (inverter or MCU) is longer than the high<br />

acceleration comm<strong>and</strong> (SPRINT function or high acceleration<br />

level)<br />

N Trouble shooting see Administrator OPTION 48<br />

N Contact authorized service engineer<br />

N Check voltage supply. Do not use extension cords. Connect<br />

the <strong>machine</strong> direct to the socket in the wall<br />

N Check mechanical parts for any malfunction. Maybe several<br />

persons were st<strong>and</strong>ing on the <strong>machine</strong> for a moment?<br />

N Remove pleated bellow from upper frame (where applicable,<br />

depending on frame).<br />

N Attention: Dangerous voltage <strong>and</strong> danger of being hurt when<br />

the device is open. Do not touch the parts inside the device