unning, cycling, cross-country, skating [inline, roller ski]<br />

Valve-cock position [1] horizontally: The distributor [2] is<br />

adjusted for lubrication [3] only in the center of the <strong>running</strong>deck<br />

[4].<br />

The valve-cock position only changes the distribution of the<br />

oil amount to the various oil-outlets (tubes).<br />

The total oil-supply amount of the oil-pump always remains<br />

constant, independent from the valve-cock position.<br />

A nearly empty oil-tank will be indicated by the control lamp<br />

“Empty Oil-tank” at the external control unit. Refill the oiltank<br />

when control lamp indicates<br />

wheelchair<br />

Valve-cock position [1] vertically: The distributor [2] is<br />

adjusted for lubrication [3] over the entire width of the<br />

<strong>running</strong>-deck [4].<br />

The valve-cock position only changes the distribution of the<br />

oil amount to the various oil-outlets (tubes). The total oilsupply<br />

amount of the oil-pump always remains constant,<br />

independent from the valve-cock position.<br />

A nearly empty oil-tank will be indicated by the control lamp<br />

“empty oil-tank” at the external control unit. Refill the oiltank<br />

when control lamp indicates. Additionally at st<strong>and</strong>ard<br />

settings the word “OIL” will flash every 1000 km at the<br />

display. If this message occurs, check the oil-level in the oiltank<br />

<strong>and</strong> refill preterm if necessary.<br />

maintenance & safety inspections<br />

The device does not have a sensor, the oil-message does not extinguish automatically. After checking the oil-level,<br />

the message has to be quit with „OPTION 01“.<br />