[10.I2] Devices without UserTerminal<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 153 of 213<br />

trouble shooting<br />

The devices without UserTerminal are equipped with an automatic error message codes via acoustic signal (bleep)<br />

indicating the device has a malfunction or needs to be lubricated or regular service. In case of error <strong>and</strong> service<br />

messages a beep-tone is given as acoustical signal. So the user of the <strong>running</strong> <strong>machine</strong> gets a feedback about<br />

error <strong>and</strong> service messages even without UserTerminal. The appropriate beep-code resounds the moment the<br />

error occurs, <strong>and</strong> afterwards when switching on the <strong>running</strong> <strong>machine</strong> if the error still exists three times in a row. To<br />

interpret the error without a display a beep-code is audible according to the error message <strong>and</strong> according to the list<br />

below:<br />

o = long beep / x = short beep<br />

0= ooooo / 1= xoooo / 2= xxooo / 3= xxxoo / 4= xxxxo / 5= xxxxx / 6 = oxxxx / 7= ooxxx / 8= oooxx / 9= oooox<br />

Example OIL message: On st<strong>and</strong>ard setting every 1000 km after switching on the device (main power switch) the<br />

acoustic signal "5 times LONG (code for "0")" <strong>and</strong> 1 time SHORT + 4 times LONG (code for "1") will be repeated 3<br />

times. Error Code list see: Devices with UserTerminal. The error messages have to be terminated with<br />

"OPTION 01". An external UserTerminal or a PC software h/p/cosmos para control ® is required for this.<br />

[10.J] Set back of error message<br />

[10.J1] Devices with UserTerminal<br />

Initiation: Running-Belt is not moving. One of the modes LED � is flashing: (manual, profile, cardio, test)<br />

[10.J1] Step Activity Keys Response / Display<br />

[01] Select of the mode for user<br />

options (OP xx)<br />

= indicates: OP01 flashing (for option no. 01)<br />

a d b<br />

! <strong>and</strong> " indicate: E.rE SEt (für Error reset)<br />

Press all 3 keys<br />

simultaneously for<br />

at least 3 seconds<br />

[02] Confirm option no. 1<br />

c<br />

§ indicates: donE to inform you that you have to<br />

delete the oil message<br />

[03] Delete message<br />

= indicates: OP 01 flashing (for option no. 01)<br />

[04] Quit option mode<br />

c<br />

b<br />

! <strong>and</strong> " indicate: E.rE SEt (für Error reset)<br />

St<strong>and</strong>-by mode<br />

� manual, profil, cardio or test is flashing<br />

With this procedure only the message E01-OIL, as well as the message E02-Service can be reset. All other error<br />

messages are caused by technical defects / malfunctions. These error messages can only be reset in the<br />

administrator-level. Please contact in this case the customer service in written form.<br />

[10.J2] Devices without UserTerminal<br />

The OIL-message as well as the SERVICE-message have to be quit by „OPTION 01”. Error messages have to be<br />

quit by „OPTION 01“ at the administrator-level. In both cases you need an „external UserTerminal“ or the PC-<br />

Software h/p/cosmos para control ® to do that . For further procedures see devices with UserTerminal.