optional settings<br />
[8.B1] OP08 Heart Rate Display Interval § indicates: Heart Rate Display Interval in seconds<br />
Einstellbereich: 0 (beat to beat) .... 1 bis 9 Sekunden<br />
Adjustable from 0 (beat to beat) .... to 9 seconds<br />
Compare: An original POLAR watch has a display interval of 5<br />
seconds<br />
$ reports: SEC<br />
OP09 Test of all displays <strong>and</strong> LEDs<br />
OP10 Enter the serial number of the device Change the values with a or d<br />
according to the nameplate<br />
Confirm the values with c<br />
OP11 Activating <strong>and</strong> de-activating speed<br />
Example: Treadmill with serial number cos30000va08-0128 on the<br />
nameplate<br />
§ reports: 300 (item number of device)<br />
$ indicates: 0008 (item number of device)<br />
% indicates: 0128 (consecutive serial numbers of this device<br />
family)<br />
Normally the speed measurement is activated / de-activated by<br />
measurement<br />
selecting the correct device type (administrator option number 3). Only<br />
in very special cases a special adjustment in option number 11 is<br />
necessary. Speed measurement can only be activated if the device<br />
has a speed sensor<br />
§ reports:<br />
0 = without speed measurement / -sensor<br />
1 = with speed measurement / -sensor<br />
(permanent control)<br />
2 = with speed measurement / -sensor<br />
(control as of speed > 2 km/h, no control < 2km/h)<br />
OP12 Setting of allowance for speed-signal- The MCU5 control unit is comparing continuously the data of the<br />
comparison (Measurement / Control) speed measurement with a calculated reference value. In order to<br />
detect problems with the speed measurement or speed control or e.g.<br />
These values do not reflect the real performance limitations due to a bad voltage supply, an allowance<br />
speed accuracy of the <strong>running</strong> belt. range can be set in this option. In case the allowance is exceeded the<br />
Accuracy of <strong>running</strong>-belt speed is higher. error message E.31 (measured speed is too high) or E. 32 (measured<br />
speed is too low) is reported.<br />
§ reports: OFF = no comparison<br />
6 = 6 % deviation is allowed<br />
8 = 8 % deviation is allowed<br />
10 = 10 % deviation is allowed