[8.B2] OP 35 Oil Interval<br />
OP 37 Interval for service message TSC<br />
(time-dependent)<br />
for technical safety control E.02 “HELP"<br />
1.000 km (treadmills)<br />
100 km (ladder ergometer)<br />
0 = no supervision<br />
100 ... 5.000 km<br />
12 month 0 … 48 month<br />
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />
© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 120 of 213<br />
optional settings<br />
OP 38 Service Interval (distance-dependent) 5.000 km (treadmill)<br />
1.000 ... 9.999 km (treadmill)<br />
"E 02" "HELP"<br />
500 km (ladder ergometer) 100... 5.000 km (ladderergometer)<br />
OP 39 Elevation: display as set point or true 1 (true value) 0 = set point<br />
value<br />
1 = true value<br />
OP 40 Speed: display as set point or true value 1 (true value) 0 = set point<br />
1 = true value<br />
OP 41 Elevation control after STOP 0 (Elevation maintains) 0 = Elevation maintains<br />
1 = Elevation gets down to 0 %<br />
OP 46 Display <strong>and</strong> setting of elevation for<br />
ladder ergometer<br />
75 (degree) 0 … 180 degree<br />
OP 47 Set back of oil- <strong>and</strong> service interval<br />
OP 48 Running-Belt-Speed at maximum (depending on the device type; (depending on the device type;<br />
frequency inverter speed<br />
OP 03)<br />
OP 03)<br />
1.00 … 99.99 km/h<br />
OP 49 Type of FI Control RS-485 Analogue, RS-485<br />
OP 51 Error statistics of the digital FI-control n.a. 0 to 9999 per type of error<br />
OP 89 System for elevation measurement (depending on the device type; (depending on the device type;<br />
OP 03)<br />
OP 03)<br />
OP 90 Load or save default setting n.a. n.a.<br />
OP 91 Total time of operation MCU<br />
(incl. st<strong>and</strong> by)<br />
n.a. 0 ... 1.193.046 h<br />
OP 92 Total Distance n.a. 0 ... 4.294.976 km<br />
OP 93 Total time of operation (incl. st<strong>and</strong>-by) n.a. 0 ... 1.193.046 h<br />
OP 94 Total time of use (motor + belt) n.a. 0 ... 1.193.046 h<br />
OP 95 MCU serial number n.a. 0000 0000 to 9999 9999<br />
OP 98 Setting for limitation of time of use n.a. n.a.<br />
OP 99 Test-Profile 99 for endurance testing in<br />
the factory / service<br />
0 = Test 99 de-activated 0 = Testprofile 99 de-activated<br />
1 = Testprofile 99 activated