[8.A2] OP44 Locking <strong>and</strong> unlocking the test mode<br />

OP45 Report mode display „index“<br />

"<br />

OP46<br />

Report mode display „elevation“ $<br />

in „Profile“ <strong>and</strong> „Test“ mode<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 104 of 213<br />

optional settings<br />

OFF = test mode is locked / not accessible<br />

1 ... 94 = test mode is unlocked / accessible up to the selected test<br />

profile number St<strong>and</strong>ard: 24<br />

selected test number = 5: The test profiles 1-5 can be selected, the<br />

test profiles 6 – 94 can not be selected<br />

0 = Display automatically switches through (Default)<br />

1 = Display permanently in MET<br />

2 = Display permanently in KJ<br />

3 = Display permanently in Watt<br />

After total switch off the default value 0 will be valid again.<br />

0 = Display automatically switches through (Default)<br />

1 = Display permanently in % or degree (°), depending on OP14<br />

2 = Display permanently in „step“<br />

After total switch off the default value 0 will be valid again.<br />

OP47 Sustain values in display resp. automatic OFF = Display values are deleted after pressing START again or<br />

„Reset“<br />

automatically after 2 minutes after having pressed STOP (Default)<br />

ON = Display values will be continued (added) after pressing START<br />

again <strong>and</strong> will not be automatically deleted by pressing STOP.<br />

Display values can only be deleted by pressing the STOP key twice<br />

(time, distance, energy).<br />

OP48 Count-Down of program-step OFF = The time-display counts up each program-step<br />

ON = The time-display counts down each program-step<br />

OP52 Output interval for printer protocol By entering a value between 0 <strong>and</strong> 100 the output interval is set in<br />

seconds for a printer directly connected to the treadmill. St<strong>and</strong>ard: 60<br />

(= Printout of all values once a minute). The value 0 disables the<br />

printing out of single values, but not the printing of headers <strong>and</strong> end<br />

results (UKK).<br />

OP53 Language settings for printer Select the language for printouts on a printer directly connected<br />

protocol<br />

to the treadmill. You can choose between six languages. Both<br />

the protocol printout as well as the test result <strong>and</strong> training<br />

recommendation of the UKK 2 km walk test are printed in the<br />

selected language.<br />

EnGL = Englisch (st<strong>and</strong>ard) SPAn = Spanish<br />

GErM = German POrt = Portuguese<br />

FrEn = French HUnG = Hungarian<br />

For a correct printout the connected printer must be compatible with<br />

PCL printer language. For special characters the ISO 8859-1 (Latin-1)<br />

font is used.