Initiation: Running-Belt is not moving. One of the modes LED � is flashing: (manual, profile, cardio, test)<br />
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />
© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 67 of 213<br />
operation<br />
[7.B5] Step no. Activity Keys Response / Display<br />
[01] Select operational mode profile<br />
Alteration of the mode (manual, profile, cardio, test) until<br />
[02] Start operational mode profile<br />
[03] Select profile no. 1 ... 6<br />
[04] Start operational mode profile:<br />
The selected profile no. 1 ... 6<br />
[05] Stop <strong>running</strong>-belt<br />
a or d<br />
c<br />
a or d<br />
c<br />
b<br />
� profile is flashing<br />
� profile is glowing<br />
� speed max. is glowing<br />
� program no. is glowing<br />
= indicates: max. speed in this profile<br />
! indicates: time in this profile<br />
$ indicates: profil no. 1<br />
� profile is glowing<br />
� speed max. is glowing<br />
� program no. is glowing<br />
= indicates: max. speed in this profile<br />
! indicates: time in this profile.<br />
$ indicates: profil no. 1 ... 6<br />
A) In case of deactivation (st<strong>and</strong>ard) in the optional<br />
functions:<br />
� profile is glowing<br />
� % is glowing, by turns with LED step<br />
� KJ <strong>and</strong> Watt are glowing by turns<br />
Running belt accelerates up to the starting-speed of the<br />
first program step, according to the "table of programs".<br />
5 seconds before the next program step there is an<br />
acoustic countdown. Start of measuring. All displays<br />
indicate the actual values. The belt stops automatically<br />
according to the profile duration. The belt can be<br />
stopped at any time with the help of b.<br />
B) In case of activation in the optional functions:<br />
" indicates: SC 3 (scaling 1 ... 6) is flashing<br />
= indicates max. speed according to the scaling (for<br />
max. speed in this profile)<br />
� speed max. is glowing<br />
! indicates time according to the scaling (for<br />
duration of this Profile)<br />
In order to enter with a or d <strong>and</strong> then c das the<br />
scaling (max. Speed, Elevation, Time <strong>and</strong> Distance).<br />
Herewith you can create more variations out of the 6<br />
st<strong>and</strong>ard Profiles. Continue with A)<br />
Running belt stops.<br />
(Deceleration time can be adjusted in the optional<br />
functions)