Initiation: Running-Belt is not moving. One of the modes LED � is flashing: (manual, profile, cardio, test)<br />

file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />

© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 67 of 213<br />

operation<br />

[7.B5] Step no. Activity Keys Response / Display<br />

[01] Select operational mode profile<br />

Alteration of the mode (manual, profile, cardio, test) until<br />

[02] Start operational mode profile<br />

[03] Select profile no. 1 ... 6<br />

[04] Start operational mode profile:<br />

The selected profile no. 1 ... 6<br />

[05] Stop <strong>running</strong>-belt<br />

a or d<br />

c<br />

a or d<br />

c<br />

b<br />

� profile is flashing<br />

� profile is glowing<br />

� speed max. is glowing<br />

� program no. is glowing<br />

= indicates: max. speed in this profile<br />

! indicates: time in this profile<br />

$ indicates: profil no. 1<br />

� profile is glowing<br />

� speed max. is glowing<br />

� program no. is glowing<br />

= indicates: max. speed in this profile<br />

! indicates: time in this profile.<br />

$ indicates: profil no. 1 ... 6<br />

A) In case of deactivation (st<strong>and</strong>ard) in the optional<br />

functions:<br />

� profile is glowing<br />

� % is glowing, by turns with LED step<br />

� KJ <strong>and</strong> Watt are glowing by turns<br />

Running belt accelerates up to the starting-speed of the<br />

first program step, according to the "table of programs".<br />

5 seconds before the next program step there is an<br />

acoustic countdown. Start of measuring. All displays<br />

indicate the actual values. The belt stops automatically<br />

according to the profile duration. The belt can be<br />

stopped at any time with the help of b.<br />

B) In case of activation in the optional functions:<br />

" indicates: SC 3 (scaling 1 ... 6) is flashing<br />

= indicates max. speed according to the scaling (for<br />

max. speed in this profile)<br />

� speed max. is glowing<br />

! indicates time according to the scaling (for<br />

duration of this Profile)<br />

In order to enter with a or d <strong>and</strong> then c das the<br />

scaling (max. Speed, Elevation, Time <strong>and</strong> Distance).<br />

Herewith you can create more variations out of the 6<br />

st<strong>and</strong>ard Profiles. Continue with A)<br />

Running belt stops.<br />

(Deceleration time can be adjusted in the optional<br />

functions)