[10.I1] E41 Error during memory initialization<br />
SETUP ERROR“ MCU<br />
or<br />
low or defective battery<br />
E50 Error of<br />
frequency inverter / motor regulation<br />
At ANALOG control of frequency inverter<br />
= „E 41“ ! „type“ " „OP03“ blinking<br />
§ „SETU“ $ „P E“ % „rrOr“ blinking<br />
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_<strong>running</strong>_<strong>machine</strong>.doc<br />
© 2012 h/p/cosmos sports & medical gmbh email@h-p-cosmos.com created 15.02.2012 printed 15.02.2012 page: 150 of 213<br />
trouble shooting<br />
<strong>running</strong> <strong>machine</strong> is still working<br />
N At MCU5 control electronic (as of manufacturing date<br />
12/2007) this error exclusively shows a defect of the option<br />
memory (FRAM). In this case, please contact h/p/cosmos <strong>and</strong><br />
request a service technician.<br />
N Optional setup restores to default factory setting <strong>and</strong> device<br />
type<br />
N By pressing the key c the device can still be used, but it is<br />
likely that individual settings <strong>and</strong> program profiles may not be<br />
available any more. Also Display readings <strong>and</strong> accuracy of<br />
speed <strong>and</strong> elevation need to be checked.<br />
N Press Start <strong>and</strong> STOP, power off <strong>and</strong> power on the device.<br />
N In case the error message E41 is still indicated, contact an<br />
authorized service technician.<br />
Either the MCU electronic may be defective or the battery may be<br />
low or defective.<br />
= „E 50“ ! „FU“ flashing<br />
§ $ % „HELP“ flashing<br />
Running <strong>machine</strong> is not functioning<br />
N Check plug no. S6 at the MCU board<br />
N Maybe defective frequency inverter<br />
N Maybe power supply too weak because of an extension cable<br />
etc.<br />
N Check power supply <strong>and</strong> power cord<br />
N Contact authorized service engineer