3 CLR HRLY (Clear Hourly Totals): To clear Hourly Totals press the “NO/CHANGE” keyto change OFF to ON and then press “YES/ENTER”. The following screen will appear:Clear Hourly Totals Screena. To clear the Hourly Totals, press the “YES/ENTER” key. All Hourly Totals will becleared and the cursor will return to the Options menu.b. To maintain the Hourly Totals, press the “NO/CHANGE” key. Hourly Totals will bemaintained and the cursor will return to the Options menu.c. A lock level of 2 or 3 will require an access code entry before allowing “Hourly Totals”reset.4 DN Occlu (Down Occlusion): This feature allows the pump to sense an occlusion pressure inthe line between the pump and the access site (e.g., a kink in the tubing between the pumpand the patient, a blockage in the access site, or a clamp left on the distal tubing). There aretwo options for this field: the “Low” setting (default setting) triggers the alarm when it detectsin-line pressures at 400 mmHg ±150 (8 ±3 psi “pounds per square inch”), or the “High”setting alarms when it detects in-line pressures at 900 mmHg ±150 (18 ±3 psi). Press“NO/CHANGE” to change the selection. When the correct pressure setting appears, pressthe “YES/ENTER” key to accept it and move the cursor to the next field.5 AIR SENS (Air In Line Sensor): This feature allows you to select the amount of air the pumpwill detect in the administration set tubing before it goes into an alarm state. The choices are0.1 ml, 0.5 ml (the default setting), 2.0 ml, and OFF. Press the “NO/CHANGE” key tochange the options until the desired setting appears on the display, and then press“YES/ENTER” to select and move the cursor to the next line.IMPORTANTINFORMATIONWhenever the Air-In-Line Sensor is set to OFF, <strong>Curlin</strong> <strong>Med</strong>icalrecommends the use of an air-eliminating filter.When the Air-In-Line Sensor is set to “OFF” and the “RUN” key is pressed at the RunOption screen, the alert message below will appear on the screen. It will also appear if theAir-In-Line is changed from the OPTIONS menu when an infusion is in progress and theAIR SENS field is accepted.Air-In-Line Sensor Off Message Screen94

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!