11.07.2015 Views

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The time format (12 hr AM/PM or 24 hr Military) selected in the BIOMED SETUP Menuwill apply in this table; and, if Military was selected, the AM/PM field will not appear here. Ifthe entire delay start screen is to be aborted, press the “NO” key at the ACCEPT field. Whenthe start time and date are entered and the data is accepted after the “YES/ENTER” key ispressed, the infusion is set to start at the programmed time. The display then returns to thenext field in the Pre-Prescription Menu.After the entire prescription program is accepted, if the pump is turned OFF and back ON,press “YES” at PROGRAM and “YES” to REPEAT Rx. The cursor will automaticallyscroll through the program. No changes will be allowed in the Pre-Prescription Menu duringthis time, thus maintaining the originally programmed Delay Start time. To change the DelayStart time, press the “NO/CHANGE” key when the Run Options Screen is displayed:Run Options ScreenThis will allow the clinician to go back to review the program and at this point a change canbe made to the delay start time.Note: If the pump is not connected to the patient’s access site at this time, the patient orcaregiver should be taught proper techniques to access the infusion site before thescheduled start time.When the “”RUN” key is pressed, the Green and Yellow LED lights will flash to indicate thatthe pump will automatically start when the delay start countdown period is up. During thedelay start time, the following screen appears:If the KVO rate is set to 0, the pump will beep ten minutes prior to the beginning of thetherapy start time. To stop the audible beep, press the “Silence” key.IMPORTANTINFORMATIONDuring the delay start period, if the KVO rate is set to 0, no fluid isinfusing. Be sure the access device is patent and has been flushedper facility policy to maintain patency during this time period. If aKVO rate is programmed, then that KVO rate will be used in theDelay Start period.2 NEXT?: If there are any changes to be made, use the up or down arrow keys to locate thefield to be changed, use the numeric keys to enter the corrected information, and press“YES/ENTER” to accept the new data. If all the fields are acceptable, move the cursor tothe “NEXT?” field and press the “YES/ENTER” key to move on to the next screen.74

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!