d. To exit this screen, press the NO/CHANGE key.3 CLR HRLY (Clear Hourly Totals): To clear Hourly Totals press the “NO/CHANGE” keyto change OFF to ON and then press “YES/ENTER”. The following screen will appear:Clear Hourly Totals Screena. To clear the Hourly Totals, press the “YES/ENTER” key. All Hourly Totals will becleared and the cursor will return to the Options Menu.b. To maintain the Hourly Totals, press the “NO/CHANGE” key. Hourly Totals will bemaintained and the cursor will return to the Options Menu.c. A lock level 2 or 3 will require an access code entry before allowing hourly total reset.4 TitrRx (Titrate Prescription): If this feature was not selected in the Pre-Prescription Menu, itwill not appear on the Options Menu. If a Titrate prescription was programmed and if thetherapy is to be titrated now, select “ON” and then press the “YES/ENTER” key to acceptand to go to the Continuous titration menu:Continuous Titration MenuThis screen allows the user to change the rate within the predefined prescription limits.a. RATE: Using the numeric keys, enter the new desired rate. When the new rate has beenentered, press the “YES/ENTER” key to move to the next field. If the titration option isused to change the rate, the new rate will then appear on the run screen and on theprescription menu whenever it is reviewed.b. ACCEPT? YES/NO: Use the up/down arrows to move to a field and change the dataentered at this time. To abort this screen entirely, press “NO” at this prompt, and thedisplay will return to the options menu. If the rate is correct, press the “YES/ENTER”key, and the new rate will automatically be accepted. The display returns to the Optionsmenu when this screen is exited.c. New values will be in effect when the Options Menu is exited.5 DN Occlu (Down Occlusion): This feature allows the pump to sense an occlusion pressurein the line between the pump and the access site— e.g., a kink in the tubing between thepump and the patient, a blockage in the access site, a clamp left on the distal tubing. Thereare two options for this field: the “Low” setting (default setting) triggers the alarm when it48

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!