11.07.2015 Views

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Resolution:LCD Display:Alert:Cause:Resolution:LCD Display:Alert:Cause:Resolution:LCD Display:Alert:Cause:Resolution:LCD Display:Alert:Cause:Resolution:LCD Display:Alert:Cause:Resolution:Recheck the field and accept it by pressing the “YES/ENTER” key.ALERT GREATER THAN MAX FIELD LIMIT, MAX = _____Unable to program a field with a value that exceeds the maximum limitValue entered is greater than the allowable limit.Recheck data entry. A value entered cannot exceed the field limit.ALERT GREATER THAN WHAT BOLS INT ALLOWSUnable to enter a # of boluses/hr that exceeds the possible numberallowed given the bolus interval# Boluses/hr value exceeds the possible number given the bolus interval(“BOLS INT”) programmed.Recheck data entry. The # of boluses/hr cannot be set for higher than thenumber allowed using the given bolus interval.ALERT INFUSION NOT IN PROGRESSInfusion not in progressModification attempted to Next Dose or Early Down Ramp field withoutan infusion in progress.Wait until infusion is in progress before modifying or modify original Rxprogrammed.ALERT INSUFFICIENT VOLUME MAX DOSES=_____Bag Volume value is insufficient to deliver the remainingOccurs whenever the prescription is changed so that Bag Volume is nowless than Amount Required for the entire therapy (based on volumealready infused plus volume required to deliver the remaining doses).Recheck data entry. If the source container contains sufficient volume tocomplete the remaining dose cycles (dose volume + KVO volume),increase the “Bag Vol”. If the volume is insufficient, decrease the“DOSE/BAG” such that the therapy can continue with the new modifiedprescription.Note: If either “Bag Vol” or “DOSE/BAG” is modified and the therapyis repeated, these fields will have to be verified against the sourcecontainer volume and prescribed prescription and changedaccordingly.ALERT INVALID ENTRYInvalid EntryData entered does not fall within the defined limits of the program.Enter data that falls within the limits of the program. Refer to the specifictherapy section in the <strong>User</strong>’s <strong>Manual</strong>.Troubleshooting125

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!