During the delay start period, if the KVO rate is set to 0, no fluid isinfusing. Be sure the access device is patent and has been flushed perfacility policy to maintain patency during this time period. If a KVOrate is programmed, then that KVO rate will be used in the Delay Startperiod.4 NEXT?: If there are any changes to be made, use the up or down arrow keys to locate thefield to be changed, use the numeric keys to enter the corrected information, and press“YES/ENTER” to accept the new data. If all the fields are acceptable, move the cursor tothe “NEXT?” field and press the “YES/ENTER” key to move on to the next screen.IMPORTANTINFORMATIONAt the following screens, the prescription information is entered to complete the programming ofthe therapy.Variable Therapies are programmed in individual dose screens, from one up to twenty-four.Before information about each individual dose is entered, the bag volume and number of totaldoses per bag are entered on the initial programming screen. Once the total number of doses isentered and accepted, the pump will subsequently display a screen for each dose to program thespecific dose amount, rate, and time:Variable Prescription Menu11 BAG Vol (IV Bag Volume): Use the numeric keys to enter the amount of fluid in the IV Bagor <strong>Med</strong>ication Reservoir (include the overfill volume).Note: The volume used for priming via the pump or for KVO is deducted from the BagVolume. Therefore, Bag Volume should be equal to or greater than the Amount To BeInfused to start the infusion.When the correct amount has been entered, press the “YES/ENTER” key to accept thisfield and move on to the next. The range for this field is 1 to 9999.2 # Doses: The Variable Therapy can be programmed to deliver from one to twenty-fourindividual programs or “doses”. Enter the total number of doses to be delivered from thepreviously entered bag volume. This number dictates the number of dose programmingscreens that will subsequently display. When the correct number of doses has been entered,press the “YES/ENTER” key to accept this field and move on to the next.3 KVO RATE: This field requires data entry using the numeric keys to set the rate at whichfluid will be delivered in a “Keep Open” state. The pump defaults to a rate of 0.1 ml/hour,can be set from 0 to 10 ml/hour. All dose rates (ml/hr) must be greater than the KVO rate.When the desired KVO rate has been entered, press the “YES/ENTER” key to accept andmove the cursor to the next field.4 NEXT?: If there are any changes to be made, use the up or down arrow keys to locate thefield to be changed, use the numeric keys to enter the corrected information, and pressVariable Therapy105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!