Also, when the Air-In-Line sensor is completely disabled and the infusion goes to an“Infusion Complete” or “Empty Bag” status, the Air Sensor setting will automatically changeto 2.0 ml.6 AUDIO (Audio Volume): This feature allows you to adjust the audio volume of the pump’salarm setting. You can enter a number from 9 (the loudest setting) to 1 (the quietest setting).When you select a number, the pump will beep at that audio level. Press the “NO” key andenter a new setting (1 - 9). Repeat until the desired setting appears on the display, and thenpress “YES/ENTER” to select it and move the cursor to the next field.7 PWR CK? (Power Check): This feature allows you to periodically recheck the battery charge.It will display the active power source of the pump, whether batteries or external power. Ifthe active source is the batteries, a graph will indicate approximately how much chargeremains in the batteries. To access this information, select “ON” and press “YES/ENTER”.The Power Source Screen will display for five seconds and return to the Options Menu.8 ACCEPT OPT?: If the changes made in the Options Menu are acceptable, press the“YES/ENTER” key. If the changes are not acceptable, use arrow keys to cursor up to anyfield for corrections, or abort all changes made in this menu by pressing the “NO” key andreturn to the previous screen.There are two remaining selections to consider from the “Run Options Screen”: NO toREVIEW and RUN to START.Reviewing or Changing the ProgramTo review or make any changes in the prescription programming, press the “NO/CHANGE”key at the Run Options screen, and the prescription screens will reappear (Changes may beinhibited by lock setting.) Changes to the prescription can be made before the start of thetherapy; however, once a therapy has started, no changes can be made to the Pre-PrescriptionScreen. It will appear only for review purposes. Attempts to change the Pre-Prescription Menuduring a new program review will cause an alert screen to be displayed, notifying the programmerthat changes will require reprogramming of the prescription.Starting the InfusionRUN: When all parameters are correct and the pump has been primed properly and connectedto the access site, press “RUN” at the Run Options screen to start the therapy. If a delayed startis programmed, the “Delay Start Count Down Screen” will appear. If no delay start isprogrammed or the delay has elapsed, the pump will begin infusing and the following screendisplays the status of the therapy:Variable Run Screen 1This information toggles with the following:112

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!