Keypad Function1 ON/OFF: Used to turn the pump on and off. When the pump is running, however, the“PAUSE” key must be used to stop the infusion first and then the “OFF” key can be pressedto turn the pump off. This requirement prevents the interruption of an infusion by a singleaccidental press of the “OFF” key.2 RUN/PAUSE: Used to start or pause the motor of the pump, which, in turn, starts orpauses fluid delivery. When the pump is running, pressing this key will pause the pump.When the pump is paused, pressing this key during the “Run Options” menu will start thepump. This key is also used to terminate a pump alarm.Note: If the cause of the alarm is not resolved when the pump is “Resumed,” the alarm willrecur.3 ⇑ Up arrow: Used to scroll the highlight bar or field cursor up on the display screen.Note: The Up arrow will not accept a selection which must be made with a YES/ENTERor NO/CHANGE key.4 ⇓ Down arrow: Used to scroll the highlight bar or field cursor down on the display screen.Note: The Down arrow will not accept a selection which must be made with aYES/ENTER or NO/CHANGE key.5 NO/CHANGE: Used to respond “NO” to data or questions presented or to reject or tochange highlighted data.Note: The <strong>Curlin</strong> <strong>Med</strong>ical pump requires you to actively change a selection. The Up arrowor Down arrow will not change a selection.6 YES/ENTER: Used to respond “YES/ENTER” to data or questions presented or to“accept” highlighted data when prompted to press “enter” key.Note: The <strong>Curlin</strong> <strong>Med</strong>ical pump requires you to affirmatively accept a selection. The Uparrow or Down arrow will not accept a selection.7 HELP/OPTIONS: Used to request a help screen when the pump is paused or is at the“Infusion Complete Screen.” It is also used to access the options screen when the pump isrunning. When the options screen is displayed, help is again available with this key. When ina help screen, use the arrow keys to scroll through the help message, and then press the helpkey again to exit help.8 ./SILENCE: Used as a decimal point when programming numeric data. Used also totemporarily silence the alarm (for one-minute intervals).9 PRIME/BOLUS: Used to prime fluid through the tubing to clear it of air or to administera patient demand bolus dose of medication in PCA therapy.10 0 - 9 Numeric keys: - Used for data entry.24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!