enter a new setting (1 – 9). Repeat until the desired setting is reached, and then press“YES/ENTER” to select and move the cursor to the next field.10 PWR CK? (Power Check): This feature allows you to periodically recheck the battery charge.It will display the active power source of the pump, whether internal batteries or externalpower. If the active source is the batteries, a graph will indicate approximately how muchcharge remains in the batteries. To access this information, select “ON” and press“YES/ENTER”. The Power Source Screen will display for five seconds and return to theOptions Menu.11 ACCEPT OPT? If the changes made in the Options Menu are acceptable, press the“YES/ENTER” key. If the changes are not acceptable, cursor up to any field for correctionsor abort all changes made in this menu by pressing the “NO” key, and return to the previousscreen.There are two remaining selections to consider from the “Run Options Screen”, NO toREVIEW and RUN to START.Reviewing or Changing the ProgramTo review or make any changes in the prescription programming, press the “NO/CHANGE”key at the Run Options screen, and the prescription screens will reappear (Changes may beinhibited by lock setting.) Changes to the prescription can be made before the start of thetherapy; however, once a therapy has started, no changes can be made to the Pre-PrescriptionScreen. It will appear only for review purposes. Attempts to change the Pre-Prescription Menuduring a new program review will cause an alert screen to be displayed, notifying the programmerthat changes will require reprogramming of the prescription.Starting the InfusionRUN: When the programming is complete and the pump has been primed properly andconnected to the access site, press the “RUN” key at the Run Option screen to start the therapy.The pump will begin infusing, and except when a LOAD DOSE or CLIN DOSE isprogrammed, the following screen will display data on the status of the therapy:IMPORTANTINFORMATIONThe amount of drug infused during the “loading dose” dependson the units chosen which may be in ml/s, mg, or mcg. Aloading dose of 5 mg will infuse 50 ml if the concentration is 0.1mg/ml.PCA Run Screen66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!