11.07.2015 Views

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

Curlin 4000 User Manual - Med-E-Quip Locators

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Run Options Screena. Press the “RUN” key to resume the therapy.b. Press the “NO” key to go back to the programming screen to make changes in thetherapy program (this feature may be blocked by a security lock, thus not allowingchanges to the program unless an access code is given). Also, remember that no changesare allowed in the first prescription menu if an infusion is in progress.c. Press the “OPTIONS” or “PRIME” keys if either of these functions is desired at thistime.Hanging a New Container2 REPEAT Rx: To repeat the present therapy and add another IV bag or reservoir with thesame prescription, press the “YES/ENTER” key at this field. If more than one therapy isprogrammed, a “Select Therapy Screen” will list all preprogrammed therapies. Select whichtherapy to repeat by moving the cursor to the therapy of choice and pressing the“YES/ENTER” key.The pump will then display the program screen with the last programmed values of thetherapy and the cursor will automatically advance through the prescription menus. You canstop the auto-advance function by pressing any key (except ON/OFF) and then complete theconfirmation of the prescription manually by pressing the “YES” key at the remaining fields.When the program is accepted, the display returns to the above “Run Options Screen.” If thecurrent therapy is still in progress when the “REPEAT Rx” function is selected, the followingscreen will appear:a. This screen is a reminder that the infusion is not complete. If the therapy is to beterminated and a new IV container added, press “YES/ENTER” to go to theprogramming screen, confirm the program and proceed with the repeat infusion.b. If the incomplete therapy is to be continued, press “NO” and the Pause Menu screen willbe displayed, then press “YES” and the Run Options screen will be displayed. To resumethe unfinished therapy, press “RUN”.Following the confirmation and acceptance of the prescription screens, a screen will appear toconfirm the dosing schedule. This screen is displayed only if the previous INT infusion wasterminated prior to the completion of the infusion.98

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!