ERROR CODESIf a pump goes into an error code, a numeric code will appear on the display screen. If this hasoccurred, turn the pump off and back on. If the error code message does not reappear, continueusing the pump.If the pump passes its start-up diagnostic tests, resume the therapy. If an error code recurs, turnthe pump off, replace it, and report the error code to the healthcare provider.ErrorCodeLCD DisplayedMessageProbable CauseCorrective Action10 Turn pump OFF/ON or ReplaceBattery or Call ProviderMotor Control Loss• Replace batteries.• Connect AC Adaptor.• Turn power off/on and resume.11 Turn pump Off/On Keyboard Buffer Full Report error code to factory.12 Air SensorAir In Line test circuit failure Report error code to factory.Turn pump Off/ONor Call provider13 Pressure Sens DNBad Down Strain Beam Replace set and Resume.Check Admin Set turn pumpOff/On14 Pressure Sens UP Check Admin Bad Up Strain BeamReplace set and Resume.Set Turn pump Off/On15 Turn pump Off/On or Call Bad EncoderReport error code to factory.Provider16 Turn pump Off/On or call Bad Analog to Digital Report error code to factory.ProviderConversion17 Turn pump OFF Call Provider Bad Clock Report error code to factory.18 Call Provider Bad Air In Line comparator Report error code to factory.register reading from FPGA.19 Turn Pump OFF Call Provider Bad Door Sensor Report error code to factory.20 Empty Lithium BatteryEmpty Lithium BatteryReport error code to factory.Call Provider21 Turn pump OffBad Tristate PinReport error code to factory.Call Provider22 Turn Pump OFFBad Test PinReport error code to factory.Call Provider23 Turn Pump OFFBad Reverence Voltage Report error code to factory.Call Provider24 Turn Pump OFFBad Motor SupplyReport error code to factory.Call Provider25 Stalled PumpBroken Motor ShaftTurn power off/on and resume.Turn pump OFF/ONCall Provider26 Turn Pump OFFBad Motor InhibitReport error code to factory.Call Provider27 Turn Pump OFFBad Motor Supply Enable Report error code to factory.Call Provider28 Turn Pump OFFCall ProviderBad Motor Logic Enable Report error code to factory.29 Low Alarm BattConnect AC AdaptTurn pump OFF/ON30 Turn Pump OFFCall Provider31 Turn Pump OFFCall Provider32 Turn Pump OFFCall Provider33 Low Alarm AudioConnect AC AdaptTurn pump OFF/ONLow Auxiliary Battery Connect pump to AC BatteryEliminator and turn power off/on topump. May require turning pumpoff/on a few times.Bad Auxiliary BatteryReport error code to factory.Audio Main Speaker LowAudio Main Speaker HighReport error code to factory.Check/replace D31. Replace PCB.Audio Auxiliary Speaker Low Connect pump to AC BatteryEliminator and turn power off/on topump. May require turning pumpoff/on a few times.Troubleshooting135

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!