CHAPTER 1: <strong>GE</strong>TTING STARTED<br />

1.2 Using the <strong>Relay</strong><br />

1.2.1 Menu Navigation<br />

The relay has three types of display messages: actual value, settings, and target messages.<br />

A summary of the menu structure for settings and actual values can be found at the<br />

beginning of chapters 5 and 6, respectively.<br />

Settings are programmable settings entered by the user. These types of messages are<br />

located within a menu structure that groups the information into categories. Navigating<br />

the menu structure is described below.<br />

Actual values include the following information:<br />

1. <strong>Motor</strong> and System Status:<br />

a. <strong>Motor</strong> status either stopped, starting, or running. It includes values such as motor<br />

load, thermal capacity used, motor speed, and instantaneous values of power<br />

system quantities.<br />

b. The status of digital inputs.<br />

c. Last trip information, including values such as cause of last trip, time and date of<br />

trip, motor speed and load at the time of trip, pre-trip temperature measurements,<br />

pre-trip analog inputs values, and pre-trip instantaneous values of power<br />

system quantities.<br />

d. Active alarms.<br />

e. <strong>Relay</strong> date and time.<br />

f. Present blocking conditions.<br />

g. General system status indication including the status of output relays, active<br />

pickup, alarm and trip conditions.<br />

2. Metering Data:<br />

a. Instantaneous current measurements including phase, differential, unbalance,<br />

ground, average, and motor load.<br />

b. RTD Temperatures including hottest RTDs.<br />

c. Instantaneous phase to phase and phase to ground voltages (depending on the<br />

VT connections), average voltage, and system frequency.<br />

d. <strong>Motor</strong> Speed<br />

e. Power Quantities including apparent, real and reactive power.<br />

f. Current and power demand including peak values.<br />

g. Analog inputs<br />

h. Vector information.<br />

3. <strong>Motor</strong> Learned Data:<br />

a. Learned and last acceleration time.<br />

b. Learned and last starting current.<br />

<strong>469</strong> MOTOR MANA<strong>GE</strong>MENT RELAY – INSTRUCTION MANUAL 1–3