CHAPTER 6: ACTUAL VALUES<br />

6.3.6 Demand Metering<br />

6.3.7 Analog Inputs<br />

PATH: ACTUAL VALUES A2 METERING DATA DEMAND METERING<br />

<br />

DEMAND [<br />

]<br />

METERING<br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

CURRENT<br />

DEMAND: 0 Amps<br />

REAL POWER<br />

DEMAND: 0 kW<br />

REACTIVE POWER<br />

DEMAND: 0 kvar<br />

APPARENT POWER<br />

DEMAND: 0 kVA<br />

PEAK CURRENT<br />

DEMAND: 0 Amps<br />

Range: 0 to 100000 A<br />

Range: 0 to 99999 kW<br />

The values for current and power demand are shown. The power demand values are not<br />

shown if the VT RATIO is programmed as “None”. Peak Demand information is cleared with<br />

the S1 <strong>469</strong> SETUP CLEAR DATA CLEAR PEAK DEMAND DATA settings. Demand is<br />

shown only for positive real and positive reactive power.<br />

PATH: ACTUAL VALUES A2 METERING DATA ANALOG INPUTS<br />

<br />

ANALOG [<br />

]<br />

INPUTS<br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

MESSA<strong>GE</strong><br />

PEAK REAL POWER<br />

DEMAND: 0 kW<br />

PEAK REACTIVE<br />

POWER<br />

PEAK APPARENT<br />

POWER<br />

ANALOG I/P 1<br />

0 Units<br />

ANALOG I/P 2<br />

0 Units<br />

ANALOG I/P 3<br />

0 Units<br />

ANALOG I/P 4<br />

0 Units<br />

ANALOG 1-2<br />

0 Percent<br />

ANALOG 1-2<br />

0 Units<br />

Range: 0 to 99999 kvar<br />

Range: 0 to 65535 kVA<br />

Range: 0 to 100000 A<br />

Range: 0 to 99999 kW<br />

Range: 0 to 99999 kvar<br />

Range: 0 to 65535 kVA<br />

Range: –50000 to 50000. Seen only if<br />

Analog Input is programmed.<br />

Range: –50000 to 50000. Seen only if<br />

Analog Input is programmed.<br />

Range: –50000 to 50000. Seen only if<br />

Analog Input is programmed.<br />

Range: –50000 to 50000. Seen only if<br />

Analog Input is programmed.<br />

Range: –5100 to 4900%. Seen only if<br />

Analog In Diff 1-2 set to %Diff<br />

Range: –100000 to 100000. Seen only<br />

if Analog In Diff 1-2 is Abs Diff<br />

<strong>469</strong> MOTOR MANA<strong>GE</strong>MENT RELAY – INSTRUCTION MANUAL 6–15