e. Building dimensions including width, length, height, <strong>and</strong> roof slope.<br />

f. Indicate compliance with AISC st<strong>and</strong>ards for hot-rolled steel <strong>and</strong> AISI st<strong>and</strong>ards for<br />

cold-rolled steel, including edition dates of each st<strong>and</strong>ard.<br />

g. Governing building code <strong>and</strong> year of edition.<br />

h. Design Loads: <strong>Inc</strong>lude dead load, roof live load, collateral loads, roof snow load, deflection,<br />

wind loads/speeds <strong>and</strong> exposure, seismic design category or effective peak<br />

velocity-related acceleration/peak acceleration, <strong>and</strong> auxiliary loads (cranes).<br />

i. Load Combinations: Indicate that loads were applied acting simultaneously with concentrated<br />

loads, according to governing building code.<br />

j. Building-Use Category: Indicate category of building use <strong>and</strong> its effect on load importance<br />

factors.<br />

k. ICC International Accreditation Service, <strong>Inc</strong>.: <strong>Inc</strong>lude statement that metal building<br />

system <strong>and</strong> components were designed <strong>and</strong> produced in an IAS Accredited Facility<br />

by an IAS Accredited Manufacturer. Metal Buidling System Manufacturer shall meet<br />

the criteria of AC 472 Inspection Programs for Manufacturer’s of Metal Building Systems.<br />

F. Welding certificates.<br />

G. Erector Certificate: Signed by manufacturer certifying that erector complies with requirements.<br />

H. Manufacturer Certificate: Signed by manufacturer certifying that products comply with requirements.<br />

I. Qualification Data: For Erector <strong>and</strong> Manufacturer.<br />

J. Material Test Reports: Signed by manufacturers certifying that the following products comply<br />

with requirements:<br />

1. Structural steel including chemical <strong>and</strong> physical properties.<br />

2. Bolts, nuts, <strong>and</strong> washers including mechanical properties <strong>and</strong> chemical analysis.<br />

3. Tension-control, high-strength, bolt-nut-washer assemblies.<br />

4. Shop primers.<br />

5. Nonshrink grout.<br />

K. Source quality-control test reports.<br />

L. Field quality-control test reports.<br />

M. Product Test Reports: Based on evaluation of comprehensive tests performed by manufacturer<br />

<strong>and</strong> witnessed by a qualified testing agency, for insulation <strong>and</strong> vapor retarders. <strong>Inc</strong>lude<br />

reports for thermal resistance, fire-test-response characteristics, water-vapor transmission,<br />

<strong>and</strong> water absorption.<br />

N. Warranties: Special warranties specified in this Section.<br />

O. Other Action Submittals:<br />

1. Door Schedule: For doors <strong>and</strong> frames. Use same designations indicated on Drawings.<br />

<strong>Inc</strong>lude details of reinforcement.<br />

Metal Building Systems 13 34 19 - 5<br />