22 00 01 PLUMBING SYSTEMS<br />

1.00 GENERAL<br />

1.01 WORK INCLUDED<br />

A. Provide labor, materials, equipment <strong>and</strong> incidentals for complete, operable plumbing<br />

systems.<br />

1.02 QUALITY ASSURANCE<br />

A. Verify location, size, depth <strong>and</strong> pressure of each utility prior to beginning work. If conditions<br />

are found that will adversely affect the installation, notify the Architect or Engineer in writing.<br />

B. Plumbing fixtures <strong>and</strong> trim of like kind shall be of the same manufacturer throughout the<br />

project, in the following categories:<br />

1. Water closets, lavatories,<br />

2. Countertop sinks<br />

3. Electric water coolers<br />

4. Emergency shower, eye <strong>and</strong> face washes<br />

5. Faucets, mixing valves (other than thermostatic mixing valves)<br />

6. Tailpiece, fixture traps, escutcheons, arm extensions, strainers<br />

7. Fixture carriers<br />

1.03 WATER USAGE REQUIREMENTS: WATER SAVING PERFORMANCE STANDARDS OF THE<br />

TEXAS COMMISSION ON ENVIRONMENTAL QUALITY ADOPTED DECEMBER 14, 2005,<br />

SHALL APPLY TO EVERY FIXTURE INCLUDED HEREIN.<br />

A. The maximum flow from a sink or lavatory faucet shall not exceed 2.20 gallons of water per<br />

minute at 60 psig.<br />

B. The maximum volume of water per flush from a toilet (water closet) shall not exceed 1.60<br />

gallons (1.6 gpf)SUBMITTALS<br />

C. Provide Submittals in accordance with Division 1, SUBMITTALS <strong>and</strong> include Manufacturer's<br />

product data sheets for the following:<br />

1. Plumbing fixtures <strong>and</strong> trim.<br />

2. Piping materials <strong>and</strong> valves.<br />

3. Equipment <strong>and</strong> accessories.<br />

D. Operation And Maintenance Data: Submit operation <strong>and</strong> maintenance data in accordance<br />

with Division 1.<br />

1.04 STANDARDS<br />

A. AUTHORITY HAVING JURISDICTION<br />

1. Perform all work in accordance with the regulations <strong>and</strong> ordinances of federal, state, <strong>and</strong><br />

local agencies, who have lawful jurisdiction over the Place of Record. Notify proper<br />

authorities for inspections as work progresses.<br />

B. CODES AND ORDINANCES<br />

1. The design <strong>and</strong> installation shall be in accordance with the applicable provisions of the<br />

following codes <strong>and</strong> ordinances. These codes <strong>and</strong> ordinances shall apply as if written<br />

here in their entirety:<br />

2006 International Plumbing Code (IPC), with any local city amendments.<br />

2006 International Energy Conservation Code (IECC), with any local city<br />

amendments.<br />

Plumbing Systems 22 00 01 - 1<br />