Attachment B<br />

Documentation of Average Strength – Trial Mixtures<br />

(ACI 301, 4.2.3.4.b)<br />

A. Summary of test record(s):<br />

Trial<br />

Mix No.<br />

No. of Test<br />

Cylinders<br />

7-day Tests<br />

Strength<br />

(psi)<br />

28-day Tests<br />

No. of Test<br />

Cylinders<br />

Stren<br />

gth<br />

(psi)<br />

Water-<br />

Cementitious<br />

Materials<br />

Ratio<br />

Slump<br />

(in)<br />

Air<br />

Content<br />

(%)<br />

Temprature<br />

(°F)<br />

B. Maximum water-cementitious materials ratio ________<br />

• Provide an interpolation calculation or plot of strength versus water-cementitious<br />

materials ratio.<br />

C. Submit the following data for each mix:<br />

1. Br<strong>and</strong>, type <strong>and</strong> amount of cement.<br />

2. Br<strong>and</strong>, type <strong>and</strong> amount of each admixture.<br />

3. Amount of water used in trial mixes.<br />

4. Proportions of each aggregate material per cubic yard.<br />

5. Gross weight per cubic yard.<br />

6. Measured slump.<br />

7. Measured air content.<br />

8. Compressive strength developed at 7 days <strong>and</strong> 28 days, from not less than three<br />

test cylinders cast for each 7 <strong>and</strong> 28 day test.<br />

Cast-in-Place Concrete 03 30 00 - 20<br />

DPR09328