11.07.2015 Views

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The <str<strong>on</strong>g>12th</str<strong>on</strong>g> <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> <str<strong>on</strong>g>Symposium</str<strong>on</strong>g> <strong>on</strong> <strong>District</strong> <strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>,September 5 th to September 7 th , 2010, Tallinn, Est<strong>on</strong>iaThere was not enough time to develop completelymodified c<strong>on</strong>trol curves for the test objects during thepresent heating seas<strong>on</strong>. On the other h<strong>and</strong>, a c<strong>on</strong>trolcurve with an adaptive c<strong>on</strong>troller is never definitive;rather it increases as more operati<strong>on</strong>al points (differentoutdoor temperatures) are added <strong>and</strong> is then graduallymodified if outer c<strong>on</strong>diti<strong>on</strong>s change. In order to receivevalues for the primary return temperature <strong>on</strong> a yearlybasis using the adaptive c<strong>on</strong>trol algorithm, the newc<strong>on</strong>trol curve needs to be modified for the entiretemperature range. During the performed field studies,the reducti<strong>on</strong> of the primary return temperature wasabout 3 °C. Even though the test period limited thenumber of tests, the temperature range was still ratherwide, including temperatures from -2 to 14 °C.It is plausible that certain circuits are more suitable fora variable flow rate, e.g., depending <strong>on</strong> hydraulicbalancing. It would also be possible to map out underwhich circumstances other heat emitters than radiators,such as fan coil heaters, can be included in a radiatorcircuit where the flow varies.ACKNOWLEDGEMENTThe Swedish <strong>District</strong> <strong>Heating</strong> Associati<strong>on</strong>, the SwedishEnergy Agency <strong>and</strong> Nordic Energy Research aregratefully acknowledged for financing this work.REFERENCES[1] Euroheat & Power, Guidelines for <strong>District</strong> <strong>Heating</strong>Substati<strong>on</strong>s, Downloaded from:http://www.euroheat.org/documents/Guidelines%20<strong>District</strong>%20<strong>Heating</strong>%20Substati<strong>on</strong>s.pdf,20081117.[2] Frederiksen, S., Wollerstr<strong>and</strong>, J., Performance ofdistrict heating house stati<strong>on</strong> in altered operati<strong>on</strong>almodes, 23rd UNICHAL-C<strong>on</strong>gress, Berlin, 1987.[3] Gummérus, P., Peterss<strong>on</strong>, S., Robust Fjärrvärmecentral(Robust <strong>District</strong> <strong>Heating</strong> Substati<strong>on</strong>), ReportA 99-223, Dept. of Energy <strong>and</strong> Envir<strong>on</strong>ment,Chalmers Univ. of Technology, Gothenburg, 1999.[5] Liao, Z., Swains<strong>on</strong>, M., Dexter, A.L., On the c<strong>on</strong>trolof heating systems in the UK, Building <strong>and</strong>Envir<strong>on</strong>ment 40 (2005) 343-351.[6] Lindkvist, H., Walletun, H., Teknisk utvärdering avgamla och nya fjärrvärmecentraler i Slagsta(Technical evaluati<strong>on</strong> of old <strong>and</strong> new districtheating substati<strong>on</strong>s in Slagsta), Report 2005:120,Swedish <strong>District</strong> <strong>Heating</strong> Associati<strong>on</strong>, 2005.[7] Ljunggren, P., Johanss<strong>on</strong>, P.-O., Wollerstr<strong>and</strong>, J.,Optimised space heating system operati<strong>on</strong> with theaim of lowering the primary return temperature,Proceedings from 11th <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> <str<strong>on</strong>g>Symposium</str<strong>on</strong>g> <strong>on</strong><strong>District</strong> <strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>, Reykjavik, 2008.[8] Peeters, L., Van der Veken, J., Hens, H., Helsen,L., D‘haeseleer, W., C<strong>on</strong>trol of heating systems inresidential buildings: Current practice, Energy <strong>and</strong>Buildings 40 (2008) 1446-1455.[9] Petitjean, R., Total hydr<strong>on</strong>ic balancing, Tour &Anderss<strong>on</strong> Hydr<strong>on</strong>ics AB, Ljung, Sweden, 1995.[10] Skagestad, B., Mildenstein, P., <strong>District</strong> <strong>Heating</strong> <strong>and</strong><strong>Cooling</strong> C<strong>on</strong>necti<strong>on</strong> H<strong>and</strong>book, published by the<str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> Energy Agency (R & D Programme <strong>on</strong><strong>District</strong> <strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>), 2002.[11] Snoek, C., Yang, L., Frederiksen, S., Korsman, H.,Optimizati<strong>on</strong> of <strong>District</strong> <strong>Heating</strong> Systems byMaximizing Building <strong>Heating</strong> System TemperatureDifferences, Report 2002:S2, <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> EnergyAgency (R & D Programme <strong>on</strong> <strong>District</strong> <strong>Heating</strong> <strong>and</strong><strong>Cooling</strong>) & NOVEM, Sittard, 2002.[12] Trüschel, A., Hydr<strong>on</strong>ic <strong>Heating</strong> Systems – TheEffect Of Design On System Sensitivity, DoctoralThesis, Chalmers University of Technology,Gothenburg, Sweden, 2002.[13] Volla, R., Ulseth, R., Stang, J., Frederiksen, S.,Johns<strong>on</strong>, A., Besant, R., Efficient substati<strong>on</strong>s <strong>and</strong>installati<strong>on</strong>s, Report 1996:N5, <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> EnergyAgency (R & D Programme <strong>on</strong> DHC) & NOVEM,Sittard, The Netherl<strong>and</strong>s, 1996.[4] Langendries, R., Low Return Temperature (LRT) in<strong>District</strong> <strong>Heating</strong>, Energy <strong>and</strong> Buildings, 12 (1988)191-200.214

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!