11.07.2015 Views

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The <str<strong>on</strong>g>12th</str<strong>on</strong>g> <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> <str<strong>on</strong>g>Symposium</str<strong>on</strong>g> <strong>on</strong> <strong>District</strong> <strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>,September 5 th to September 7 th , 2010, Tallinn, Est<strong>on</strong>iabuilding mass will start to interact with the air mass <strong>and</strong>thus stabilizing the c<strong>on</strong>tinuing temperature drop, i.e. thel<strong>on</strong>g time c<strong>on</strong>stant [10].The influence of external <strong>and</strong> internal free heat is largeenough that when these heat sources interact withother parts of the thermal process it hides shorter heatload reducti<strong>on</strong>s in the ambient temperature. This canbe seen in Figure 7 where it is shown that although theaverage indoor temperature is not noticeably affectedthere is still a somewhat larger deviati<strong>on</strong> in the indoortemperature which implies that there is indeed a higherlevel of temperature flux within the air mass <strong>and</strong> thatthis is triggered by the heat load reducti<strong>on</strong>s. Thec<strong>on</strong>trol policies used during this work obviously set ahigh bar for the c<strong>on</strong>trol system to h<strong>and</strong>le, but as theaverage hardware develops it should be possible toimplement such techniques <strong>on</strong> a larger scale.Figure 8 gives another clear indicati<strong>on</strong> of just howsubstantial such sources of free energy can be. Thisextra heating due to solar radiati<strong>on</strong> through thewindows directly interacts with the mass of air insidethe building, thus raising the temperature.In additi<strong>on</strong> to being able to help save energy usage in abuilding temporary heat load reducti<strong>on</strong>s also form thebackb<strong>on</strong>e of DSM <strong>and</strong> LC, in which the goal is tomanage the heat load (kW) rather than the energyusage (kWh).FUTURE WORKIn the future we plan to further develop models in orderto dynamically estimate the temperature flux withinbuildings <strong>and</strong> develop theoretical <strong>and</strong> practicalinterfaces for incorporating this data dynamically intothe c<strong>on</strong>trol systems.ACKNOWLEDGEMENTThis work has been financed by Blekinge Institute ofTechnology <strong>and</strong> NODA Intelligent Systems AB.REFERENCES[1] N. Björsell, C<strong>on</strong>trol strategies for heating systems,University-College of Gävle-S<strong>and</strong>viken.[2] F. Wernstedt, P. Davdiss<strong>on</strong> <strong>and</strong> C. Johanss<strong>on</strong>,―Dem<strong>and</strong> Side Management in <strong>District</strong> <strong>Heating</strong>Systems‖, in Proc. Of Sixth <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g>C<strong>on</strong>ference <strong>on</strong> Aut<strong>on</strong>omous Agents <strong>and</strong> MultiagentSystems, H<strong>on</strong>olulu, Hawaii, USA, 2007.[3] L. Jensen. ―Nattsänkning av temperatur I flerbostadshus‖,R64:1983, Byggforskningsrådet, 1983(In Swedish).[4] H. Lindkvist <strong>and</strong> H. Wallentun. ―Utvärdering av niofjärrvärmecentraler i Slagsta‖ Report ZW 04/05,ZW Energiteknik, 2004 (In Swedish)[5] F.B. Morris, J.E. Braun <strong>and</strong> S.J. Treado ―Experimental<strong>and</strong> simulated performance of optimalc<strong>on</strong>trol of building thermal storage‖, ASHRAETransacti<strong>on</strong>s, Vol. 100, No. 1, 1994[6] E. Isfält <strong>and</strong> G. Bröms. ―Effekt- och energibesparinggenom förenklad styrning och drift avinstallati<strong>on</strong>ssystem I byggnader‖, ISRN KTH/IT/M--22--E. Instituti<strong>on</strong>en för Installati<strong>on</strong>steknik. KungligaTekniska Högskolan, 1992. (In Swedish)[7] S. Ruud. ―Energimyndighetens program förpassivhus och lågenergihus‖ Remissversi<strong>on</strong> 2009-03-10. Forum för Energieffektiva byggnader, 2009.(In Swedish)[8] F. Wernstedt <strong>and</strong> C. Johanss<strong>on</strong>. ―Dem<strong>on</strong>strati<strong>on</strong>sprojektinom effekt och laststyrning‖. ISBN 978-91-7381-041-8, The Swedish <strong>District</strong> <strong>Heating</strong>Associati<strong>on</strong>, 2009. (In Swedish)[9] J. Skoog, ―PM avseende komfort‖, ÅF-InfrastrukturAB, 2005. (In Swedish)[10] C. Norberg. ―Direktverk<strong>and</strong>e elradiatorers regleringoch k<strong>on</strong>strukti<strong>on</strong>‖ Vattenfall Utveckling AB, Rapportnr F-90:5, Älvkarleby, 1990. (In Swedish)[11] L. Olss<strong>on</strong> Ingvarss<strong>on</strong>, S. Werner. ―Building massused as short term heat storage‖ in Proceedings ofThe 11th <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> <str<strong>on</strong>g>Symposium</str<strong>on</strong>g> <strong>on</strong> <strong>District</strong><strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>. Reykjavik, Icel<strong>and</strong>, 2008.249

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!