11.07.2015 Views

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

12th International Symposium on District Heating and Cooling

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The <str<strong>on</strong>g>12th</str<strong>on</strong>g> <str<strong>on</strong>g>Internati<strong>on</strong>al</str<strong>on</strong>g> <str<strong>on</strong>g>Symposium</str<strong>on</strong>g> <strong>on</strong> <strong>District</strong> <strong>Heating</strong> <strong>and</strong> <strong>Cooling</strong>,September 5 th to September 7 th , 2010, Tallinn, Est<strong>on</strong>iaSince the use of an insulating backfill is more efficientwith huge diameters, a DN 700 pipe was chosen for anexample scenario. An annual average for the flow <strong>and</strong>return temperature was taken into account. For thecalculati<strong>on</strong> of the required backfill volume in theembedment, 0.2 m space in every directi<strong>on</strong> of the pipeswas estimated. It is important for the calculati<strong>on</strong> to take<strong>on</strong>ly the additi<strong>on</strong>al costs into account. That means theprice difference between cable s<strong>and</strong> <strong>and</strong> the insulati<strong>on</strong>material including the transportati<strong>on</strong> costs.A comm<strong>on</strong> value of 6% was chosen for the requiredrate of return (i).The net present value C 0 was calculated with thefollowing equati<strong>on</strong>:CTt0 I (R t) (1 i)t 1(13)The internal rate of return shown in Fig. 4 wascalculated with the IRR- functi<strong>on</strong> in Excel.Table 1 Scenario for insulati<strong>on</strong> materialParameter Value UnitLength of the districtheating line:5000 mNominal diameter: DN 700Average flowtemperature:Average returntemperature:Annual hours ofoperati<strong>on</strong>:Heat price (at the time ofthe invest):Required volume ofinsulati<strong>on</strong> material:95 °C50 °C8760 h15 €/MWh th1.85 m 3Additi<strong>on</strong>al specific costs: 16 - 17 €/m 3Required volume for thewhole line:Heat loss with use of thematerial:Heat loss without use ofthe material:9250 m 369.6 W/m90.7 W/mEnergy savings: 23.3 %Annual savings of thewhole line:924 MWh thAdditi<strong>on</strong>al investment (I): 148,000 – 157,000 €Required rate of return: 6.0 %Time of cash flow: 20 anet present value (20 years) [€]60,00050,00040,00030,00020,00016 €/m 3 17 €/m 316 €/m 3NPV10,000internal17 €/m 3rate ofreturn00.0% 1.0% 2.0% 3.0%growth rate of the heat price10.0%8.0%6.0%4.0%2.0%0.0%Fig. 4 NPV <strong>and</strong> IRR of the scenario defined in Table 1depending <strong>on</strong> the additi<strong>on</strong>al specific costs of the insulati<strong>on</strong>material.The results in Fig. 4 show, that the additi<strong>on</strong>al specificcosts should be below 17 €/m 3 in order to get a positivevalue spread, assumed that the required rate of returnis 6 %. A reducti<strong>on</strong> of specific costs of 5% (16 €/m 3 )results in an increase of the value spread by 1%. Thenet present value after 20 years rises about 10,000 €.The growth rate of the heat price is difficult to predict,but has an important influence within the given periodof 20 years. Presumably the heat price is mainlyinfluenced by emissi<strong>on</strong> trading, governmental subsidies<strong>and</strong> the development of the fossil fuel price.Other scenarios may estimate higher growth rates, butin order to get realistic results, the rate was varied from0% to 3,5%.Table 2 gives an example of materials with low heatc<strong>on</strong>ductivity that could be interesting to use as backfill.It is obvious to look for natural products, because of theprice <strong>and</strong> envir<strong>on</strong>mental regulati<strong>on</strong>s.internal rate of returnAnnual growth rate ofthe heat price:0 – 3.5 %300

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!