Another issue is the cost of the refrigeration. Buildings and infrastructure may be a major cost factor for large<br />

amounts of refrigeration. Effort should be made to reduce the refrigeration at 4 K and at higher temperatures since<br />

the cost (infrastructure and ownership) is direct function of the amount of heat to be removed.<br />

One key issue is the availability of manufacturers. The largest manufacturer of 4 K coolers is Sumitomo in Japan,<br />

which has bought out all of its competitors except for Cryomech. No American company has made a large helium<br />

refrigerator or liquefier in the last 10 years; the industrial capacity to manufacture large helium plants ended with<br />

the <strong>Superconducting</strong>-Super-Collider in 1993. Development funding may be needed for U.S. companies to insure<br />

that reliable domestic coolers will be available in the future. Development of an intermediate-sized cooler (between<br />

small laboratory-scale devices and large helium liquefiers) would be desirable to enable a system with multiple<br />

processor modules.<br />

6.4.4 COOLING – ROADMAP AND FUNDING<br />

A roadmap for the development of cryocoolers for an SCE-based, large-scale computer is shown in figure below.<br />

The funding profile needed to maintain development pace is listed in the accompanying table. More details are<br />

presented in Appendix L: Multi-Chip Modules and Boards. (The full text of this appendix can be found on the CD<br />

accompanying this report.)<br />

126<br />

I.<br />

Trade -<br />

offs<br />

1.<br />

Cryo<br />

Req<br />

docum<br />

ent<br />

2. Cryo<br />

Test Bench<br />

Design<br />

2.<br />

Cryo<br />

Test<br />

Bench<br />

3. Cryo<br />

Test Bench<br />

Fabrication<br />

and Qual<br />

3.<br />

Cryo<br />

Test<br />

Bench<br />

qualified<br />

4. Prototype<br />

Design<br />

4.<br />

Prototype<br />

Cryocooler<br />

5. Prototype<br />

Fab and Test<br />

MILESTONES<br />

5.<br />

Prototype<br />

qualified<br />

2006 2007 2008 2009 2010<br />

TABLE 6-6. COOLER DEVELOPMENT COSTS ($M)<br />

Year 2006 2007 2008 2009 2010 Total<br />

Cooler Development 1.3 0.9 1.1 0.6 0.6 4.5<br />

Total Investment 1.3 0.9 1.1 0.6 0.6 4.5