R&S ® <strong>WinIQSIM2</strong><br />

Graphical User Interface<br />

AWGN - Noise Generator<br />

The value range of this parameter is automatically adjusted depending on the selected<br />

instrument. The maximum ratio minimum noise bandwidth to system bandwidth is determinate<br />

by the max sample clock of the selected instrument and is calculated so that the<br />

overall bandwidth, i.e. "System BW" x "Minimum Noise"/"System BW Ratio" has to be<br />

less or equal to the sampling rate of the selected instrument.<br />

Remote command:<br />

​[:​SOURce]:​AWGN:​BWIDth:​RATio​ on page 204<br />

Noise Bandwidth - AWGN<br />

(Additive Noise and Noise Only)<br />

Indicates the real noise bandwidth. The value is indicated when AWGN state is "On".<br />

Note: The noise signal is not generated arbitrarily for a particular bandwidth, but instead<br />

it is generated in steps. Noise therefore also occurs outside the set system bandwidth.<br />

The noise bandwidth can not exceed the sampling rate of the baseband signal since white<br />

Gaussian noise is generated and added offline to the baseband signal. In case of "Noise<br />

Only" mode, the noise bandwidth is also determined by and can not exceed the sampling<br />

rate set with the parameter "Sample Rate".<br />

Remote command:<br />

​[:​SOURce]:​AWGN:​BWIDth:​NOISe?​ on page 204<br />

Target CW Frequency - AWGN<br />

(CW Interferer mode only)<br />

Sets the desired frequency of the sine in "CW Interferer" mode.<br />

The range of this parameter is limited to ± ("Symbol Rate" + "Sample Rate")/4<br />

Remote command:<br />

​[:​SOURce]:​AWGN:​FREQuency:​TARGet​ on page 206<br />

Resulting CW Frequency - AWGN<br />

(CW Interferer mode only)<br />

Indication of the actual CW frequency of the sinusoidal signal in "CW Interferer" mode.<br />

The resulting CW Frequency Offset is the correction of the desired value based on generating<br />

an integer multiple of periods out of the output sequence length.<br />

Remote command:<br />

​[:​SOURce]:​AWGN:​FREQuency:​RESult?​ on page 205<br />

5.11.1.2 Noise Power Configuration And Output Results<br />

The interfering signal is configured in the "Noise/Interferer Power Configuration and Output<br />

Results" section.<br />

Set Power via - AWGN<br />

(Additive Noise only)<br />

Selects the mode for setting the noise power.<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />