R&S ® <strong>WinIQSIM2</strong><br />

Remote Control Commands<br />

SOURce:BB:DM Subsystem<br />

Signal Order Decimal value of bits<br />

Marker 1<br />

Marker 2<br />

LSBit 1<br />

2<br />

Burst = LSBit 16<br />

LevAtt1 LSBit 32<br />

CWMod LSBit 64<br />

Hop MSBit 128<br />

The data can also be sent as a binary block, each binary block being a 2-byte value in<br />

which the 16 bits represent the binary values (16-bit unsigned integer, 2 bytes, LSByte<br />

first). When binary data transmission is in use, command<br />

:SYSTem:COMMunicate:GPIB:LTERminator EOI should be used to set the<br />

termination character mode to ‘EOI control data message only’ so that a random LF in<br />

the data sequence is not interpreted as End, thereby prematurely terminating the data<br />

transmission. The command ...LTER STANdard resets the mode.<br />

For query purposes, the command :FORMat ASCii | PACKed can be used to switch<br />

between the formats. The byte sequence is defined in the IEC bus standard as 'most<br />

significant byte first'<br />

Note: C-Lists are created in binary format. However, if you need the C-List in ASCII<br />

format, e.g. for creating a waveform file with R&S <strong>WinIQSIM2</strong>, see the example in ​chapter<br />

7.2.3, "Creating an ASCII C-List <strong>Manual</strong>ly", on page 184.<br />

*RST has no effect on data lists. This command is without query.<br />

Setting parameters:<br />

<br />

Example:<br />

Usage:<br />

string<br />

BB:DM:CLIS:SEL 'c_list1'<br />

selects the control list.<br />

BB:DM:CLIS:DATA 0,0,0,0,8,8,8,0,0,0,0...<br />

enters the control values in list c_list1. In the example, only ramps<br />

for marker 4 are set.<br />

Setting only<br />

<strong>Manual</strong> operation: See "Edit Control List" on page 78<br />

[:SOURce]:BB:DM:CLISt:DELete <br />

The command deletes the specified control list from the default directory. The default<br />

directory is set using command MMEM:CDIRectory. A path can also be specified, in<br />

which case the files in the specified directory are deleted. The file extension may be<br />

omitted. Only files with the file extension *.dm_iqc will be deleted.<br />

Setting parameters:<br />

<br />

<br />