R&S ® <strong>WinIQSIM2</strong><br />

Graphical User Interface<br />

Baseband Block<br />

The filter parameter offered ("Roll Off Factor" or "B x T") depends on the currently selected<br />

filter type.<br />

Remote command:<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​APCO25​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​COSine[:​ROLLoff]​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​GAUSs​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​PGAuss​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​RCOSine​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​SPHase​ on page 242<br />

Cut Off Frequency Factor - Digital Modulation<br />

(available for filter parameter Lowpass and APCO25 (LSM) only)<br />

Sets the value for the cut off frequency factor. The cut off frequency of the filter can be<br />

adjusted to reach spectrum mask requirements.<br />

Remote command:<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​LPASs​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​LPASSEVM​ on page 242<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​APCO25Lsm:​GAUSs​ on page 243<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​APCO25Lsm:​LOWPass​ on page 243<br />

Bandwidth - Digital Modulation<br />

Determines the bandwidth of the cosine filter, so that the function H(f) = 0 is fulfilled for<br />

f >= (1+RollOff)*Bandwidth/2.<br />

Remote command:<br />

​[:​SOURce]:​BB:​DM:​FILTer:​PARameter:​COSine:​BANDwidth​ on page 243<br />

Impulse Length - Digital Modulation<br />

Displays the number of filter tabs. If the check box is activated, the most sensible parameter<br />

values are selected. The value depends on the coherence check. If the check box<br />

is deactivated, the values can be changed manually.<br />

Remote command:<br />

​[:​SOURce]:​BB:​DM:​FILTer:​ILENgth:​AUTO​ on page 241<br />

​[:​SOURce]:​BB:​DM:​FILTer:​ILENgth​ on page 241<br />

Oversampling - Digital Modulation<br />

Determines the upsampling factor. If the check box is activated, the most sensible parameter<br />

values are selected. The value depends on the coherence check. If the check box<br />

is deactivated, the values can be changed manually.<br />

Remote command:<br />

​[:​SOURce]:​BB:​DM:​FILTer:​OSAMpling:​AUTO​ on page 241<br />

​[:​SOURce]:​BB:​DM:​FILTer:​OSAMpling​ on page 241<br />

More - Filter - Digital Modulation<br />

Calls the menu for displaying the filter characteristic of the currently selected filter.<br />