R&S ® <strong>WinIQSIM2</strong><br />

Remote Control Commands<br />

R&S Signal Generator Waveform and List Format<br />

The tag contains the data for the marker and control signals in the control list or the marker<br />

signals of ARB waveforms. To select which of these signals is defined, [TRACE] and the<br />

associated number are used. For ARB waveforms it is only meaningful to define marker<br />

signals (on ARB multi segment waveforms these tags will be ignored).<br />

Setting parameters:<br />

[TRACE]<br />

Specifies the name of the marker or control signal.<br />

You may choose from the following names:<br />

MARKER; BURST; LEVATT; CW MODE; HOP, MAP<br />

[#] Specifies the number in the case of control signals and marker<br />

signals with the same name. There is a choice between 4 markers<br />

and 3 LEVATT signals. Lines LEVATT 1 and 2 are needed for<br />

internal purposes and should not be used.<br />

Pos<br />

Specifies in ASCII format the number of the position in the<br />

sequence, with effect from which the binary state of the marker or<br />

of the control signal changes from 0 to 1 or from 1 to 0.<br />

Val Specifies the binary state of the marker or of the control signal {0;<br />

1} from Pos x to Pos x+1 exclusive in ASCII format.<br />

Example: {MARKER LIST 1: 0:0;10:1;20:0;30:1}<br />

BB:DM:CLIS:TAG? 'MARKER LIST 1'<br />

queries the content of the MARKER LIST 1 tag of the selected<br />

control list file.<br />

Response: '0:0;10:1;20:0;30:1'<br />

the marker setting for samples 0 to 9 = 0 (low), for 10 to 19 = 1<br />

(high) and for 20 to 29 = 0. From sample 30 onward the marker<br />

setting = 1.<br />

Example: {LEVATT LIST 1: 0:0;10:1;20:0;30:1}<br />

BB:DM:CLIS:TAG? 'LEVATT LIST 1'<br />

queries the content of the LEVATT LIST 1 tag of the selected<br />

control list file.<br />

Response: '0:0;10:1;20:0;30:1'<br />

level attenuation applies to data values 10 to 19 (high) and from<br />

data value 30 onward.<br />

Usage:<br />

Setting only<br />

{WAVEFORM-Length: #I0Q0I1Q1...IxQx...IN-1QN-1…}<br />

(mandatory for waveforms)<br />

The tag contains the actual waveform data or multi segment waveform data (I/Q stream).<br />

Use the ​TYPE tag to define wheather the waveform file contains a normal waveform or<br />

a multi segment waveform.<br />

The following figure shows the prinziple of multi segment work mode.<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />