R&S ® <strong>WinIQSIM2</strong><br />

Remote Control Commands<br />

R&S Signal Generator Waveform and List Format<br />

Example:<br />

Usage:<br />

Multi segment waveform<br />

{WAVEFORM-1201:<br />

#I 0,Seg0 ,Q 0,Seg0 ,I 1,Seg0 ,Q 1,Seg0 ,...I 99,Seg0 ,Q 99,Seg0 ,I 0,Seg1 ,Q 0,Seg1 ,I 1,Seg1 ,<br />

Q 1,Seg1 ,… I 199,Seg1 ,Q 199,Seg1 }<br />

2 segments: segment 0 with 100 I/Q pairs; segment 1 with 200 I/<br />

Q pairs. Each I/Q pair consist of 2*16 bit = 4 bytes<br />

Setting only<br />

{MWV_SEGMENT_COUNT: NumOfSeg}<br />

(mandatory for multi segment waveforms)<br />

The tag contains the number of segments in the multi segment waveform in ASCII integer<br />

format.<br />

Example: {MWV_SEGMENT_COUNT: 2}<br />

Multi segment waveform with 2 segments<br />

Usage:<br />

Setting only<br />

{MWV_SEGMENT_LENGTH: SamplesSeg0, SamplesSeg1, …, SamplesSegN-1}<br />

(mandatory for multi segment waveforms)<br />

The tag contains a list of I/Q sample lengths for every segment in the multi segment<br />

waveform in ASCII integer format.<br />

Example: {MWV_SEGMENT_LENGTH: 100,200}<br />

2 segments: 100 samples in segment 0 and 200 samples in segment<br />

1.<br />

Usage:<br />

Setting only<br />

{MWV_SEGMENT_START:<br />

SampleStartOffsetSeg0, SampleStartOffsetSeg1, …, SampleStartOffsetSegN-1}<br />

(mandatory for multi segment waveforms)<br />

The tag contains a list of I/Q sample start offsets for every segment in the multi segment<br />

waveform in ASCII integer format.<br />

Example: {MWV_SEGMENT_START: 0,100}<br />

2 segments with 100 samples in segment 0 and 200 samples in<br />

segment 1.<br />

Sample start offset of first segment 0 is 0 samples, start offset of<br />

next segment 1 is the sample length of segment 0 = 100 samples.<br />

Usage:<br />

Setting only<br />

{MWV_SEGMENT_CLOCK_MODE: Mode}<br />

(mandatory for multi segment waveforms)<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />