R&S ® <strong>WinIQSIM2</strong><br />

Graphical User Interface<br />

Main Window - Signal Flow Diagram<br />

Main difference between signal generation in real time and with the signal generation<br />

software<br />

Some of the hardware specific components of the instruments are not relevant for<br />

R&S <strong>WinIQSIM2</strong>, because R&S <strong>WinIQSIM2</strong> is not based on real time hardware. For this<br />

reason, the following features are not supported:<br />

●<br />

●<br />

●<br />

Trigger<br />

Clock<br />

Marker delay<br />

In the "Filter" settings dialog, the R&S <strong>WinIQSIM2</strong> provides the following additional<br />

parameters:<br />

●<br />

●<br />

"Impulse length"<br />

Displays the number of filter tabs. If the check box is activated, the most sensible<br />

parameter values are selected. The value depends on the coherence check. If the<br />

check box is deactivated, the values can be changed manually.<br />

"Oversampling"<br />

Determines the upsampling factor. If the check box is activated, the most sensible<br />

parameter values are selected. The value depends on the coherence check. If the<br />

check box is deactivated, the values can be changed manually.<br />

When the digital standard is activated, a coherence check is performed. The entries are<br />

checked.<br />

The following parameters are part of the check:<br />

●<br />

●<br />

●<br />

●<br />

"Sequence Length"<br />

"Impulse Length"<br />

"Oversampling"<br />

instrument limits.<br />

When the coherence check is positive, the waveform is generated and the internally used<br />

parameter values are displayed in the gray fields.<br />

5.9.2 Working with the AWGN Block<br />

For a detailed description of the settings provided in the AWGN block, refer to ​chapter<br />

5.11, "AWGN - Noise Generator", on page 121.<br />

Adding AWGN to the Baseband Signal<br />

1.<br />

In the "AWGN" block diagram, click "Config".<br />

The "AWGN Settings" dialog opens.<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />

43