14.06.2014 Views

R&S WinIQSIM2 Software Manual - Rohde & Schwarz

R&S WinIQSIM2 Software Manual - Rohde & Schwarz

R&S WinIQSIM2 Software Manual - Rohde & Schwarz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R&S ® <strong>WinIQSIM2</strong><br />

Automation of R&S <strong>WinIQSIM2</strong><br />

Remote Control Basics<br />

Instrument responses<br />

Instrument responses (response messages and service requests) are messages the<br />

instrument sends to the controller after a query. They can contain measurement results,<br />

instrument settings and information on the instrument status.<br />

6.1.1.3 LAN Interface<br />

For remote control via a network, the controller and the PC on that the R&S <strong>WinIQSIM2</strong><br />

is installed (if not the same) must be connected via the LAN interface to a common network<br />

with TCP/IP network protocol. They are connected using a commercial RJ45 cable.<br />

<strong>Software</strong> for remote control and the VISA program library must be installed on the controller.<br />

VISA library<br />

Instrument access via VXI-11 protocols is usually achieved from high level programming<br />

platforms using VISA as an intermediate abstraction layer. VISA encapsulates the low<br />

level VXI or GPIB function calls and thus makes the transport interface transparent for<br />

the user. See ​chapter 6.1.1.1, "VISA Libraries", on page 129 for details.<br />

IP address<br />

Only the IP address or the computer name (LAN device name) is required to set up the<br />

connection. The IP address/computer name is part of the "visa resource string" used by<br />

the programs to identify and control the instrument.<br />

Forms of the VISA resource string:<br />

TCPIP::host address[::LAN device name][::INSTR]<br />

or<br />

TCPIP::host address::port::SOCKET<br />

where<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

TCPIP designates the network protocol used<br />

host address is the IP address or host name of the device<br />

LAN device name defines the protocol and the instance number of a sub-instrument:<br />

– inst0 selects the VXI-11 protocol (optional, default)<br />

INSTR indicates the instrument resource class (optional)<br />

port determines the used port number<br />

SOCKET indicates the raw network socket resource class<br />

Example:<br />

In case the R&S <strong>WinIQSIM2</strong> and the controller are installed on the same PC, the IP<br />

address 127.0.0.1 is used. Hence the valid visa resource string is:<br />

TCPIP::127.0.0.1::INSTR<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />

131

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!