R&S ® <strong>WinIQSIM2</strong><br />

Remote Control Commands<br />

MMEMory Subsystem<br />

operating system, e.g. CLOCK$, CON, AUX, COM1...COM4, LPT1...LPT3, NUL and<br />

PRN.<br />

In the R&S Signal Generator all files in which lists and settings are stored are given a<br />

characteristic extension. The extension is separated from the actual file name by a dot<br />

(see ​chapter 7.3.2, "Extensions for User Files", on page 187 for an overview of the file<br />

types).<br />

The two characters "*" and "?" function as "wildcards", meaning they are used for selecting<br />

several files. The "?" character represents exactly one character, while the "*" character<br />

represents all characters up to the end of the file name. "*.*" therefore stands for<br />

all files in a directory.<br />

When used in conjunction with the commands, the parameter is specified<br />

as a string parameter with quotation marks. It can contain either the complete path<br />

including the drive, only the path and the file name, or only the file name. The file name<br />

must include the file extension. The same applies for the parameters<br />

and .<br />

Depending on how much information is provided, either the values specified in the<br />

parameter or the values specified with the commands MMEM:MSIS (default drive) and<br />

MMEM:CDIR (default directory) are used for the path and the drive settings in the commands.<br />

Before the instrument settings can be stored in a file, they have to be stored in an intermediate<br />

memory using common command *SAV . The specified number is<br />

subsequently used in the ​:​MMEMory:​STORe:​STATe​ command. Also, subsequently to<br />

loading a file with instrument settings with command ​:​MMEMory:​LOAD:​STATe​, these<br />

settings have to be activated with the common command *RCL .<br />

7.3.2 Extensions for User Files<br />

The following table lists all available file extensions for user files.<br />

Table 7-1: List of the automatically assigned file extensions in the instrument<br />

Function/Digital<br />

Standard<br />

List type Contents File suffix<br />

Instrument State Settings Instrument settings *.savrcl<br />

Import Settings Settings Settings *.import<br />

"Arbitrary Waveform<br />

Generator"<br />

Waveform<br />

ARB waveforms<br />

ARB multi segment waveforms<br />

*.wv<br />

Waveform ARB multi carrier settings *.arb_multcarr<br />

Configuration<br />

data<br />

Configuration file for creation of multisegment<br />

ARB waveforms<br />

*.inf_mswv<br />

Play List ARB Sequencing List *.wvs<br />

"DM" Data List Digital modulation data *.dm_iqd<br />

*.tdm<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />