R&S ® <strong>WinIQSIM2</strong><br />

Remote Control Commands<br />

SOURce:BB:DM Subsystem<br />

This command sends the bit data to the selected data list, which is overwritten. The data<br />

can also be sent as block data in binary or PACKed format, each byte being interpreted<br />

as 8 data bits. In this case, command :SYSTem:COMMunicate:GPIB:LTERminator<br />

EOI should be used to set the termination character mode to ‘EOI control data message<br />

only’ so that a random LF in the data sequence is not interpreted as End, thereby prematurely<br />

terminating the data transmission. The command ...LTER STAN resets the<br />

mode.<br />

The query reads out the data part of the data list. If the query is expanded by using the<br />

two parameters and , the list is read out in smaller sections. Start and<br />

Length are expressed in bits. Without the parameters the total length is always read out<br />

starting from address 1. The command :FORMat ASCii | PACKed can be used to<br />

select the data format. The byte sequence is defined in the IEC bus standard (read/write<br />

most significant byte first). *RST has no effect on data lists.<br />

Parameters:<br />

<br />

Example:<br />

Example:<br />

integer<br />

BB:DM:DLIS:SEL 'dlist1'<br />

selects data list dlist1. If the file does not yet exist, it is created.<br />

BB:DM:DLIS:DATA 1,1,1,0,0,0,1,1,0,1...<br />

sends the specified data to file dlist1. Any data already present is<br />

overwritten.<br />

BB:DM:DLIS:SEL 'dlist1'<br />

selects data list dlist1.<br />

FORM ASCI<br />

selects ASCII data transmission format.<br />

BB:DM:DLIS:DATA? 2048,1024<br />

queries the data starting at bit 2048 for 1024 bits.<br />

<strong>Manual</strong> operation: See "Data List Editor" on page 75<br />

[:SOURce]:BB:DM:DLISt:DATA:APPend <br />

The command appends the bit data onto the end of the existing data in the selected data<br />

list. This means that existing content in the data list is not overwritten. By this means very<br />

long data lists can be built up piecemeal. The data format is as specified in command<br />

SOURce:BB:DM:DLISt:DATA.<br />

The command cannot be used with an empty data list, such as one that has just been<br />

created, for example. In this case the command SOURce:BB:DM:DLISt:DATA must first<br />

be used to enter modulation data in the list.<br />

*RST has no effect on data lists.<br />

Setting parameters:<br />

<br />

0 | 1 {,0 | 1 } | block data<br />

<strong>Software</strong> <strong>Manual</strong> 1008.0858.42 ─ 10<br />

255