<strong>The</strong>me A: Connecting the Pearl River Delta RegionA normal single glass with thickness of 3 mm, heat transfer coefficient (U) valueof 5.7 W/(m 2·k) and shading coefficient of 0.93 (DEST-H building materialslibrary).B- <strong>Building</strong> with Insulated wall: it has two layer reinforced concrete (5+5 cm),which separated by a insulation layer of polystyrene with 4 cm thickness and thethermal conductivity of 0.047 W/(m.ºC) [2]. In addition, the wall has a thin layerof gypsum mortar and plaster for inside. Fig.4 shows the details of suggestedinsulated wall. <strong>The</strong> experiences show that the construction cost for hollow blockwall and insulated wall is the same.C- <strong>Building</strong> with Double glass windows: we just used of normal double glasseswith 3+6+3 mm thickness instead single glasses in the windows of block wallbuilding. <strong>The</strong> U value of normal double glass was 3.4 W/(m 2·K) and its shadingcoefficient was 0.90 (DeST-h building materials library). <strong>The</strong> construction cost ofdouble glass windows is approximately 10 $/m 2 higher than one layer glasswindows in the previous methods (A & B).Figure 3: Details of the block wall.116