<strong>The</strong>me B: Creating a livable, healthy and environmentally viable citiesunmodeled dynamics of the system or purposefully neglected dynamics throughlumping can be reflected in the lumped mathematical model through parameterestimation.6.5 Step 5 – Cavity open (Airflow mode [9])<strong>The</strong> fifth step was conducted for two days while the indoor, outdoor and diagonalmodes were randomly varied (Aug 22-24, 2007). <strong>The</strong> sampling time was 1 minute,and the number of data points was 3,027. Similar to Step 3, air flow modes 5 and 6occurred in System 1 and modes 7 and 8 in System 2. Table 8 shows the results ofparameter estimation. <strong>The</strong> average difference between the simulated and measuredtemperatures were 1.72℃ (System 1) and 0.97℃ (System 2).Table 8: Comparison <strong>The</strong> estimated and literature values with the cavity openSystem 1 System 2ξ52.20 3.02ξ61.19 2.58ξ70.39 0.48eq.(13) Δ T 3.58 2.14hca ,27.03 6.47ξ230.26 0.88ξ240.87 0.52ξ82.62 2.69ξ92.68 1.11ξ101.02 0.25eq.(14) Δ T 2.15 0.74hca ,39.51 3.99ξ230.26 0.88ξ240.87 0.52eq. (15) ξ112.11 2.83ξ121.88 2.00ξ131.01 0.42Δ T 1.02 2.13hca,47.24 5.62ξ230.26 0.88512