<strong>The</strong>me B: Creating a livable, healthy and environmentally viable citiesFigure 6: comparison of inside circulation result6.2 Step 2 – Outside circulation (Airflow modes [3]-[4])Six experiments were conducted on July 31, 2007. <strong>The</strong> sampling time was 1second, and the number of data points were 2,510(System 1) and 1,797(System 2).Table 4 shows the estimated unknown parameters of Eqs. (17) and (18). <strong>The</strong>average differences between simulated and measured values were 8.33cm/s and5.70cm/s.As in inside circulation, ξ 17Table 4: Unknown parameters in Outside circulationSystem 1 System 2ξ160 0eq. (17) ξ17 31.48 0.2789f 16.327 0.1793ξ18 0.016 0.0628eq. (18)ξ19 0.378 0.0898pw -0.101Pa -0.137Pauca,w 1.28cm/s 1.75cm/sSimulation 17.0098 17.6938ucaMeasurement 16.5459 17.9466is the dominant for determination of f for outsidecirculation. <strong>The</strong>re is also a significant difference between the two systems.For the surface wind pressure ( p w ) of Eq. (18), the negative pressure was dominantfor both systems, causing suction out of the cavity (corresponding to cases withCp