Basic ladder instructions (continued)<br />

6F3B0253<br />

7. Instructions<br />

FUN<br />

No.<br />

Name Expression Function Steps Speed<br />

(µs)<br />

Page<br />

− Counter C CNT Q Counts the number of cycles<br />

E A B the count input (C) comes ON<br />

while the enable input (E) is<br />

ON, and turns ON output (Q)<br />

when the count reaches to the<br />

value specified by A. B is a<br />

counter register.<br />

2 22.6 132<br />

− Master control set ⎥−−[ MCS ]−⎢ Turns OFF power rail between 1 3.75<br />

− Master control reset ⎥−−[ MCR ]−⎢ MCS and MCR when MCS<br />

input is OFF.<br />

1<br />

(in a<br />

pair)<br />

133<br />

− Jump control set ⎥−−[ JCS ]−⎢ Jumps from JCS to JCR when 1 2.75<br />

− Jump control reset ⎥−−[ JCR ]−⎢ JCS input is ON.<br />

1<br />

(in a<br />

pair)<br />

134<br />

− End ⎥−−[ END ]−⎢ Indicates end of main program<br />

or sub-program.<br />

1 1.4 135<br />

Data transfer instructions<br />

FUN<br />

No.<br />

Name Expression Function Steps Speed<br />

(µs)<br />

Page<br />

018 Data transfer −[ A MOV B ]− Transfers data of A to B. 3 4.2 136<br />

019 Double-word<br />

data transfer<br />

−[ A+1⋅A DMOV B+1⋅B ]− Transfers double-word data<br />

of A+1⋅A to B+1⋅B.<br />

3 7.2 137<br />

020 Invert transfer −[ A NOT B ]− Transfers bit-inverted data of<br />

A to B.<br />

3 4.6 138<br />

022 Data exchange −[ A XCHG B ]− Exchanges data of A with B. 3 6.5 139<br />

024 Table initialize −[ A TINZ (n) B ]− Transfers data of A to n<br />

registers starting with B.<br />

3 140<br />

025 Table transfer −[ A TMOV (n) B ]− Transfers data of n registers<br />

starting with A to n registers<br />

starting with B.<br />

3 141<br />

026 Table invert −[ A TNOT (n) B ]− Transfers bit-inverted data of<br />

transfer<br />

n registers starting with A to<br />

n registers starting with B.<br />

3 142<br />

090 Multiplexer −[ A MPX (n) B → C ]− Transfers data from the<br />

register specified by B in the<br />

table, size n starting with A,<br />

to C.<br />

5 70.6 176<br />

091 Demultiplexer −[ A DPX (n) B → C ]− Transfers data from A to the<br />

register specified by B in the<br />

table, size n starting with C.<br />

5 71.5 177<br />

Basic Hardware and Function 107<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net