7. Instructions<br />

Expression<br />

A<br />

Input Output<br />

NC contact<br />

Function<br />

NC (normally closed) contact of device A.<br />

When the input is ON and the device A is OFF, the output is turned ON.<br />

Execution condition<br />

Input Operation Output<br />

OFF Regardless of the state of device A OFF<br />

ON When device A is OFF ON<br />

When device A is ON OFF<br />

118 <strong>T1</strong>-<strong>16S</strong> User’s <strong>Manual</strong><br />

6F3B0253<br />

Operand<br />

Name Device Register Constant Index<br />

X Y R S T. C. XWYWRWSW T C D I J K<br />

A Device √ √ √ √ √ √<br />

Example<br />

Coil Y022 comes ON when the devices X000 and R001 are both OFF.<br />

X000<br />

R001<br />

Y022<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net