The followings are examples of index modifications.<br />

I<br />

RW10<br />

! CAUTION<br />

J<br />

D0201⋅D0200<br />

NOTE<br />

When I = 0, it designates RW10.<br />

When I = 1, it designates RW11.<br />

When I = -1, it designates RW09.<br />

When I = 10, it designates RW20.<br />

When I = -10, it designates RW00.<br />

6F3B0253<br />

6. Programming Information<br />

When J = 0, it designates D0201⋅D0200.<br />

When J = 1, it designates D0202⋅D0201.<br />

When J = 2, it designates D0203⋅D0202.<br />

When J = -1, it designates D0200⋅D0199.<br />

When J = -2, it designates D0199⋅D0198.<br />

Be careful that the registers do not exceed the address range by the index<br />

modification. The address range is not checked by the <strong>T1</strong>-<strong>16S</strong>.<br />

Substitutions of values into index registers and index modifications can be<br />

used any times in a program. Normally, the program will be easier to see if<br />

a value substitution into an index register is positioned immediately before<br />

the index modification.<br />

Basic Hardware and Function 87<br />