1. System Configuration<br />

1.1 Introducing the <strong>T1</strong>-<strong>16S</strong><br />

14 <strong>T1</strong>-<strong>16S</strong> User’s <strong>Manual</strong><br />

6F3B0253<br />

The <strong>T1</strong>-16 is compact, block style, high-performance programmable controller with a<br />

range of 16 to 144 input and output points.<br />

The figure below shows the <strong>T1</strong> Series line-up. The <strong>T1</strong> Series consists of the total 16<br />

types.<br />

<strong>T1</strong> Series <strong>T1</strong> <strong>T1</strong>-16 <strong>T1</strong>-MDR16<br />

<strong>T1</strong>-MAR16<br />

<strong>T1</strong>-MDR16D<br />

<strong>T1</strong>-28 <strong>T1</strong>-MDR28<br />

<strong>T1</strong>-MAR28<br />

<strong>T1</strong>-MDR28D<br />

<strong>T1</strong>-40 <strong>T1</strong>-MDR40<br />

<strong>T1</strong>-MAR40<br />

<strong>T1</strong>-MDR40D<br />

<strong>T1</strong>S <strong>T1</strong>-<strong>16S</strong> <strong>T1</strong>-MDR<strong>16S</strong>S<br />

<strong>T1</strong>-MDR<strong>16S</strong>C<br />

<strong>T1</strong>-MDR<strong>16S</strong>SD<br />

<strong>T1</strong>-MDR<strong>16S</strong>CD<br />

<strong>T1</strong>-40S <strong>T1</strong>-MDR40S<br />

<strong>T1</strong>-MAR40S<br />

<strong>T1</strong>-MDR40SD<br />

I/O points:<br />

The <strong>T1</strong> Series are available in five models, <strong>T1</strong>-16, <strong>T1</strong>-28, <strong>T1</strong>-40, <strong>T1</strong>-40S and <strong>T1</strong>-<br />

<strong>16S</strong>. Each model has the following I/O points.<br />

<strong>T1</strong>-16 <strong>T1</strong>-<strong>16S</strong> <strong>T1</strong>-28 <strong>T1</strong>-40 <strong>T1</strong>-40S<br />

Input 8 points 14 points 24 points<br />

Output 8 points<br />

(6 relay plus 2 slid-state)<br />

Expansion No Up to 8 I/O<br />

modules.<br />

Total up to<br />

144 points.<br />

14 points<br />

(12 relay plus<br />

2 slid-state)<br />

16 points<br />

(14 relay plus 2 solid-state)<br />

No 2 option cards plus<br />

1 expansion rack or unit.<br />

Total up to 382 points.<br />

The <strong>T1</strong>-<strong>16S</strong> can expand its I/O points by connecting I/O modules. Up to eight I/O<br />

modules can be connected. If eight 16-point I/O modules are connected to the <strong>T1</strong>-<br />

<strong>16S</strong>, it can control up to 144 points.<br />

<strong>CTi</strong> <strong>Automation</strong> - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net