6F3B0253<br />

6. Programming Information<br />

Device/<br />

register<br />

Name Function<br />

SW07 Clock/calendar (Year) Lower 2 digits of the calendar year<br />

(01, 02, ... )<br />

SW08 Clock/calendar (Month) Month (01, 02, ... 12) They are stored in<br />

SW09 Clock/calendar (Day) Day (01, 02, ... 31) the lower 8 bits by<br />

SW10 Clock/calendar (Hour) Hour (00, 01, ... 59) BCD code<br />

SW11 Clock/calendar (Minute) Minute (00, 01, ... 59)<br />

SW12 Clock/calendar (Second) Second (00, 01, ... 59)<br />

SW13 Clock/calendar (Week) Day of the week<br />

(Sun = 00, Mon = 01, ... Sat = 06)<br />

SW14 − Reserved<br />

SW15 Peripheral support priority Bit 8 (S158) is used to select peripheral support priority<br />

SW16 Mode of special input<br />

functions<br />

Used to select the special input functions<br />

SW17 Input filter constant Used to set the input filter constant<br />

SW18 Preset values for high Used to set the preset values for high speed counters<br />

SW19<br />

SW20<br />

SW21<br />

speed counter<br />

SW22 Count values for high Present count values of the high speed counters are<br />

SW23 speed counter stored<br />

SW24 High speed counter control<br />

flags<br />

Control flags for the high speed counters<br />

SW25 − Reserved<br />

SW26 Mode of special output<br />

functions<br />

Used to select the special output functions<br />

SW27 Special output control flags Control flags for the pulse/PWM output<br />

SW28 Special output frequency<br />

setting<br />

Output frequency setting for the pulse/PWM output<br />

SW29 PWM output duty setting Pulse duty setting for the PWM output<br />

SW30 Analog setting value 1 Input value of the analog setting adjuster V0<br />

SW31 Analog setting value 2 Input value of the analog setting adjuster V1<br />

SW32 − Reserved<br />

SW33 − Reserved<br />

SW34 TL-F10 send data TOSLINE-F10 transmission data (send to master)<br />

SW35 TL-F10 receive data TOSLINE-F10 transmission data (receive from master)<br />

SW36 PRG port station address Used to set the programmer port station address<br />

(1 to 32)<br />

SW37 PRG port parity Used to set the programmer port parity (0=none,<br />

1=odd)<br />

SW38 PRG port response delay Used to set the programmer port response delay time<br />

(0 to 30: 0 to 300ms)<br />

NOTE<br />

(1) These devices are set by the <strong>T1</strong>-<strong>16S</strong> operating system. These devices<br />

are read only for user.<br />

(2) Devices marked as (down) are set in the ERROR mode. Therefore<br />

these devices cannot be used in the user program.<br />

Basic Hardware and Function 83<br />